CIRCUIT BREAKERS
Showing 1–24 of 48 results
-
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
TeSys Schneider Electric Overload Relays 30 – 40amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.SKU: Overload5 -
CIRCUIT BREAKERS
TeSys Schneider Electric Overload Relays 23 – 32amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.SKU: Overload6 -
-
CIRCUIT BREAKERS
TeSys Schneider Electric Overload Relays 18 – 23amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.SKU: Overload7 -
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
ABB SACE Tmax XT1B 160 Breaker 25A
A complete range of moulded case circuit-breakers up to 3200 A.
All the circuit-breakers, both three-pole and four-pole, are available in the fixed version; sizes T4 and T5 in the plug-in version and T4, T5, T6, and T7 also in the withdrawable one.
* High breaking capacity in compact dimensions
High values of short circuit breaking capacity are guaranteed at different voltage levels, without compromising overall dimensions.* Flexibility of use
Thermomagnetic and electronic trip units are available for use in AC/DC or in AC only. It is possible to interchange trip units keeping the
same breaking part, so that installation can be upgraded with fewer costs.* Advanced protection
A complete range of electronic trip units is suitable for different level of protection, even enhancing selectivity values with Early Fault
Detection and Prevention algorithm.SKU: ABB XT1B -
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
ABB SACE Tmax XT1B 160 Breaker 20A
A complete range of moulded case circuit-breakers up to 3200 A.
All the circuit-breakers, both three-pole and four-pole, are available in the fixed version; sizes T4 and T5 in the plug-in version and T4, T5, T6, and T7 also in the withdrawable one.
* High breaking capacity in compact dimensions
High values of short circuit breaking capacity are guaranteed at different voltage levels, without compromising overall dimensions.* Flexibility of use
Thermomagnetic and electronic trip units are available for use in AC/DC or in AC only. It is possible to interchange trip units keeping the
same breaking part, so that installation can be upgraded with fewer costs.* Advanced protection
A complete range of electronic trip units is suitable for different level of protection, even enhancing selectivity values with Early Fault
Detection and Prevention algorithm.SKU: ABB TXB2 -
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
ABB SACE Tmax XT1B 160 Breaker 32A
A complete range of moulded case circuit-breakers up to 3200 A.
All the circuit-breakers, both three-pole and four-pole, are available in the fixed version; sizes T4 and T5 in the plug-in version and T4, T5, T6, and T7 also in the withdrawable one.
* High breaking capacity in compact dimensions
High values of short circuit breaking capacity are guaranteed at different voltage levels, without compromising overall dimensions.* Flexibility of use
Thermomagnetic and electronic trip units are available for use in AC/DC or in AC only. It is possible to interchange trip units keeping the
same breaking part, so that installation can be upgraded with fewer costs.* Advanced protection
A complete range of electronic trip units is suitable for different level of protection, even enhancing selectivity values with Early Fault
Detection and Prevention algorithm.SKU: ABB TXB3 -
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
ABB MCB Switch 3 POLE
Trip Free mechanism10KA short circuit breaking capacity for B and C Low power consumption,thus cost effective and energy savingFinger safe terminal IP20 degree of protectionDual Terminal Facility15 Plate Arc chute for effective arc quenchingsilver graphite contacts for enhance lifeAccessories switchPerformance and safetyPositive contact indicatorReliability and continuity of serviceSuitable for both DESB and switch boardShort Circuit breaking capacity 3KA MCBProtection against overload and short Circuit breaking capacity 3KA
SKU: 284 -
ACCESSORIES, CIRCUIT BREAKERS, DISTRIBUTION BOARDS, ELECTRICAL INDUSTRIAL, Electro
ABB Contactor AF400-30-22 100-250V
ACCESSORIES, CIRCUIT BREAKERS, DISTRIBUTION BOARDS, ELECTRICAL INDUSTRIAL, ElectroABB Contactor AF400-30-22 100-250V
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 100-250 V, AC/DC
Categories
- Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors
SKU: n/a -
CIRCUIT BREAKERS
Contactor Schneider Telemecanique
TC1-D9511 series contactors are suitable for use in circuits of AC 50Hz or 60Hz, rated insulation voltage 660V,rated operating voltage 380V/400V in AC-3 type, rated operating current up to 125A, form making, breaking frequently starting & controlling AC motors.
SKU: TC1-D9511 -
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
ABB Contactor A26-30-10 24V 50Hz / 24V 60Hz
A26 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting.
SKU: ABB1 -
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
ABB Contactor A16-30-10 600V 50Hz
A16 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A… series 1-stack 3-pole contactors are of the block type design.
SKU: ABB2 -
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
Schneider Electric MCB 2pole 63A Isolator Switch
Features
* Current Rating – 63A
* Product Range – Multi 9
* Product or Component Type – Isolator Switch
* Rating – 63A
*Number of Poles – 2
*Voltage Rating 240 V ac
* Breaking capacity – 6000A
* Reference No – 24343SKU: Schneider10 -
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
ABB Contactor – A12-30-10 220V 50Hz/190V 60Hz-
A12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A… series 1-stack 3-pole contactors are of the block type design.
SKU: ABB3 -
-
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
Easy9 miniature circuit breaker- 2P – 25 A – C curve – 6000 A – 230 V
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, ElectroEasy9 miniature circuit breaker- 2P – 25 A – C curve – 6000 A – 230 V
Schneider Electric Easy9 Miniature Circuit Breaker- 2P – 6 A – C Curve – 6000 A – 230 V
Main range Easy9device application Distributionproduct or component type Miniature circuit-breakerdevice short name Easy9 MCBPoles 2Pnumber of protected poles 2[In] rated current 25 Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1
6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1suitability for isolation Yes conforming to IEC 60898-1Complementary network frequency 50/60 Hz[Ue] rated operational voltage 220 V AC 50/60 Hz
400 V AC 50/60 Hzmagnetic tripping limit 5…10 x In[Ics] rated service breaking capacity 6 kA 100 % x Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60898-1[Uimp] rated impulse withstand voltage 4 kV conforming to IEC 60898-1contact position indicator Yescontrol type Togglelocal signalling Withoutmounting mode Clip-onmounting support DIN rail9 mm pitches 4height 81 mmwidth 36 mmdepth 66.5 mmcolour Grey (RAL 7035)mechanical durability 10000 cycleselectrical durability 4000 cyclesconnections – terminals Tunnel type terminal (top or bottom) 1…25 mm² rigid
Tunnel type terminal (top or bottom) 1…16 mm² flexibletightening torque 2 N.m top or bottomearth-leakage protection WithoutEnvironment standards IEC 60898-1product certifications CEIP degree of protection IP20 conforming to IEC 60529pollution degree 2tropicalisation 2relative humidity 95 % at -5…60 °Cambient air temperature for operation -5…60 °Cambient air temperature for storage -40…85 °CSKU: n/a -
CIRCUIT BREAKERS
TeSys Schneider Electric Overload Relays 4-6amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.SKU: Overload1