Berliac 1mm single PVC
Single-core cables are manufactured according to BS-6004/NIS-172 standards and can be installed in conduit, in cable trunking and in cable ducting or where there is deemed little risk of mechanical damage. These cables can be clipped direct, on cable tray, embedded or in free air. These cables are not intended to be laid underground.
Construction:
Conductors: Solid or stranded plain annealed copper wire (class 1 or class 2) to BS, EN 60228.
Insulation: PVC
Sheath: PVC
Voltage rating (U0/U) 300/500V
Conductor temp 70°C
Min, bending radius 4 x overall diameter of cable.
₦5,750.00
Vendor Information
- Vendor: Electric Mall
- 5.00 rating from 1 review
- CABLE AND CABLE MANAGEMENT, SINGLE CORE WIRE
Berliac 2.5mm single PVC
Single-core cables are manufactured according to BS-6004/NIS-172 standards and can be installed in conduit, in cable trunking and in cable ducting or where there is deemed little risk of mechanical damage. These cables can be clipped direct, on cable tray, embedded or in free air. These cables are not intended to be laid underground.
Construction:
Conductors: Solid or stranded plain annealed copper wire (class 1 or class 2) to BS, EN 60228.
Insulation: PVC
Sheath: PVC
Voltage rating (U0/U) 300/500V
Conductor temp 70°C
Min, bending radius 4 x overall diameter of cable.
SKU: n/a - ARMOURED CABLE
Berliac 185mm x 4core PVC/SWA/PVC Armoured Cable
Armoured Cables are manufactured to BS-6346/IEC 60502 Standards. Typically, the construction of an Aluminium or steel wire armoured cable comprises six components:
- Conductor: This is usually a plain stranded Copper Conductor.
- Insulation: Materials such as Poly-Vynyl Chloride (PVC) or Cross-linked Polyethylene (XLPE) provide good temperature resistance and excellent dielectric strength providing enhanced electrical properties.
- Bedding: This is a layer to create a protective barrier between armour and insulation.
- Armour: A steel or aluminium armour provides mechanical protection to allow the cable to withstand the mechanical stresses to which it is exposed.
- Sheath: the constituent parts of the cable are held together by a sheath offering a further level of protection. Black Poly-Vinyl Chloride sheaths can be carbon-loaded for UV stability.
- Voltage: Voltage ratings of 600/1000V, 6.35/11kV and 19/33kV
SKU: n/a - FLAT CABLES
Berliac Flat 1mm+Earth x 2core PVC
This is used for domestic wiring and installations. Can be installed in fixed installations in dry or damp premises clipped to surface, on trays or in free air where the risk of mechanical damage would not be an issue. Suitable for laying in conduit or trunking where mechanical protection is required.
Construction:
Conductors: Solid or stranded plain annealed copper wire (class 1 or class 2) to BS, EN 60228.
Insulation: PVC
Sheath: PVC
Voltage rating (U0/U) 300/500V
Conductor temp 70°C
Min, bending radius 4 x overall diameter of cable.
SKU: n/a - ARMOURED CABLE
Barliac 240mm x 1core PVC/PVC Unarmoured Cable
Armoured Cables are manufactured to BS-6346/IEC 60502 Standards. Typically, the construction of an aluminium or steel wire armoured cable comprises five components:
- Conductor: This is usually a plain stranded Copper Conductor.
- Insulation: Materials such as Poly-Vynyl Chloride (PVC) or Cross-linked Polyethylene (XLPE) provide good temperature resistance and excellent dielectric strength providing enhanced electrical properties.
- Bedding: This is a layer to create a protective barrier between armour and insulation.
- Sheath: the constituent parts of the cable are held together by a sheath offering a further level of protection. Black Poly-Vinyl Chloride sheaths can be carbon-loaded for UV stability.
- Voltage: Voltage ratings of 600/1000V, 6.35/11kV and 19/33kV
SKU: n/a - SINGLE CORE WIRE
Doncaster Cables 1.5mm Single Core – Red
Product Description
Manufactured to BS 6004:2012 Table 3
Annealed Stranded Copper Conductor / PVC Insulated / PVC Sheathed. 300/500V
Designed for use in light industrial and domestic wiring. These cables are particularly suited for installation as meter tails and are intended for fixed installation in dry or damp premises.
These cables can be installed in conduit, in cable trunking and in cable ducting. Or where there is deemed little risk of mechanical damage these cables can be clipped direct, on cable tray, embedded or in free air. These cables are not intended to be laid underground.
Product Details
Harmonisation Code Nominal Cross Sectional Area of Conductor (mm2) Nominal Stranding of Conductor (mm) Nominal Radial Thickness of insulation (mm) Nominal Radial Thickness of sheath (mm) Overall Diameter Lower Limit (mm) Overall Diameter Upper Limit (mm) Approximate Weight(kg/km) National Type 1.0 1 / 1.13 0.6 0.8 3.8 4.5 26 National Type 1.5 1 / 1.38 0.7 0.8 4.2 4.9 35 National Type 2.5 1 / 1.78 0.8 0.8 4.8 5.8 55 National Type 4.0 7 / 0.85 0.8 0.9 5.4 6.8 75 National Type 6.0 7 / 1.04 0.8 0.9 6.0 7.4 95 National Type 10.0 7 / 1.35 1.0 0.9 7.2 8.8 155 National Type 16.0 7 / 1.70 1.0 1.0 8.4 10.5 225 National Type 25.0 7 / 2.14 1.2 1.1 10.0 12.5 340 National Type 35.0 7 / 2.52 1.2 1.1 11.0 13.5 445 SKU: n/a - DISTRIBUTION BOARDS, DISTRIBUTION BOARDS
ABB 12 Way Three Phase Distribution Board
Available in kit form for over-the counter-supply, the latest generation sub-distribution solution from ABB has been tailored to meet the needs of all segments of the building industry.
Main construction features:
• Structure in epoxy coated metal sheets, 1mm thickness
• Wall installation for indoor environments
• Degree of protection – IP43 with door / Mechanical resistance IK 07
• Busbar rating: 250A
• Number of ways: 4, 8, 12, 16, 20, 24
• Compliance with IEC BS EN 61439 1-2
• Simple wiring of all cabinets, both horizontally and vertically
• Easy internal accessibility for wiring operations and maintenance
• Pre-packaged kits for specific applications (e.g. surge protection, metering)SKU: n/a