C120N – circuit breaker – 4P – 100A – C curve
range of product | C120 | |
---|---|---|
range | Acti 9 | |
product name | C120 | |
product or component type | Miniature circuit-breaker | |
device short name | C120N | |
device application | Distribution | |
poles description | 4P | |
number of protected poles | 4 | |
[In] rated current | 100 A at 30 °C | |
network type | AC | |
trip unit technology | Thermal-magnetic | |
curve code | C | |
breaking capacity | 10000 A Icn at 230…400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 500 V DC conforming to EN/IEC 60947-2 | |
suitability for isolation | Yes conforming to IEC 60947-2 |
network frequency | 50/60 Hz | |
---|---|---|
[Ue] rated operational voltage | 380…415 V AC 50/60 Hz <= 500 V DC 220…240 V AC 50/60 Hz 440 V AC 50/60 Hz 230…400 V AC 50/60 Hz | |
magnetic tripping limit | 5…10 x In | |
[Ics] rated service breaking capacity | 7500 A 75 % conforming to EN/IEC 60898-1 – 230…400 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 – 440 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 – 380…415 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 – <= 500 V DC | |
limitation class | 3 conforming to EN/IEC 60947-2 | |
[Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 | |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-2 | |
contact position indicator | Yes | |
control type | Toggle | |
local signalling | ON/OFF indication | |
mounting mode | Clip-on | |
mounting support | 35 mm symmetrical DIN rail | |
comb busbar and distribution block compatibility | NO | |
9 mm pitches | 12 | |
height | 81 mm | |
width | 108 mm | |
depth | 73 mm | |
net weight | 0.82 kg | |
colour | White | |
mechanical durability | 20000 cycles | |
electrical durability | 5000 cycles conforming to IEC 60947-2 | |
connections – terminals | Tunnel type terminals1…50 mm² rigid Tunnel type terminals1.5…35 mm² flexible | |
wire stripping length | 15 mm | |
tightening torque | 3.5 N.m | |
earth-leakage protection | Separate block |
₦60,000.00
Vendor Information
- Vendor: Electric Mall
- 5.00 rating from 1 review
- ARMOURED CABLE
Berliac 185mm x 4core PVC/SWA/PVC Armoured Cable
Armoured Cables are manufactured to BS-6346/IEC 60502 Standards. Typically, the construction of an Aluminium or steel wire armoured cable comprises six components:
- Conductor: This is usually a plain stranded Copper Conductor.
- Insulation: Materials such as Poly-Vynyl Chloride (PVC) or Cross-linked Polyethylene (XLPE) provide good temperature resistance and excellent dielectric strength providing enhanced electrical properties.
- Bedding: This is a layer to create a protective barrier between armour and insulation.
- Armour: A steel or aluminium armour provides mechanical protection to allow the cable to withstand the mechanical stresses to which it is exposed.
- Sheath: the constituent parts of the cable are held together by a sheath offering a further level of protection. Black Poly-Vinyl Chloride sheaths can be carbon-loaded for UV stability.
- Voltage: Voltage ratings of 600/1000V, 6.35/11kV and 19/33kV
SKU: n/a - TRANSFORMER
BETA 750KVA/33/0.415V COPPER/COPPER WINDING TRANSFORMER
Produced within a power range between 10 – 100.000 kVA , up to 170 kV high voltage level, three phase or single phase, oil immersed, ONAN, ONAF, OFWF, with Off-Load or On-Load Tap Changer, used both external and internal.
Dimensions of transformer conservator are determined and designed after several heat calculations of the oil stored in expansion tank and oil level changes by heat.
Being open to atmosphere, oil pressure changes continuously in Conservator Type Transformers due to thermal effects and exchange of air is dehumidified via air breather silicagel.SKU: n/a - SINGLE CORE WIRE
Doncaster Cables 1.5mm Single Core – Red
Product Description
Manufactured to BS 6004:2012 Table 3
Annealed Stranded Copper Conductor / PVC Insulated / PVC Sheathed. 300/500V
Designed for use in light industrial and domestic wiring. These cables are particularly suited for installation as meter tails and are intended for fixed installation in dry or damp premises.
These cables can be installed in conduit, in cable trunking and in cable ducting. Or where there is deemed little risk of mechanical damage these cables can be clipped direct, on cable tray, embedded or in free air. These cables are not intended to be laid underground.
Product Details
Harmonisation Code Nominal Cross Sectional Area of Conductor (mm2) Nominal Stranding of Conductor (mm) Nominal Radial Thickness of insulation (mm) Nominal Radial Thickness of sheath (mm) Overall Diameter Lower Limit (mm) Overall Diameter Upper Limit (mm) Approximate Weight(kg/km) National Type 1.0 1 / 1.13 0.6 0.8 3.8 4.5 26 National Type 1.5 1 / 1.38 0.7 0.8 4.2 4.9 35 National Type 2.5 1 / 1.78 0.8 0.8 4.8 5.8 55 National Type 4.0 7 / 0.85 0.8 0.9 5.4 6.8 75 National Type 6.0 7 / 1.04 0.8 0.9 6.0 7.4 95 National Type 10.0 7 / 1.35 1.0 0.9 7.2 8.8 155 National Type 16.0 7 / 1.70 1.0 1.0 8.4 10.5 225 National Type 25.0 7 / 2.14 1.2 1.1 10.0 12.5 340 National Type 35.0 7 / 2.52 1.2 1.1 11.0 13.5 445 SKU: n/a
There are no reviews yet.