Dark Light
, ,

EZC100N4100 Circuit breaker Easypact EZC100N – TMD – 100 A – 4 poles 3d


Main
range of product
EasyPact
product or component type
Circuit breaker
device short name
Easypact EZC100N
circuit breaker name
Easypact EZC100N
device application
Distribution
poles description
4P
protected poles description
3t
network type
AC
DC
network frequency
50/60 Hz
[In] rated current
100 A at 40 °C
[Ui] rated insulation voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-2
[Ue] rated operational voltage
550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2
breaking capacity code
N
breaking capacity
10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
5 kA Icu at 125 V DC 1P conforming to IEC 60947-2
5 kA Icu at 250 V DC 2P conforming to IEC 60947-2
5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
18 kA Icu at 380…400 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity
5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 125 V DC conforming to IEC 60947-2
2.5 kA at 250 V DC conforming to IEC 60947-2
2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
9 kA at 380…400 V AC 50/60 Hz conforming to IEC 60947-2
7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation
Yes conforming to IEC 60947-2
utilisation category
Category A
trip unit name
TM-D
trip unit technology
Thermal-magnetic
trip unit rating
100 A at 50 °C
protection type
Overload protection
Short-circuit protection
pollution degree
3 conforming to IEC 60947
Complementary
control type
Toggle
mounting mode
Fixed
mounting support
Backplate
upside connection
Front
downside connection
Front
mechanical durability
8500 cycles
electrical durability
Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
connection pitch
25 mm
local signalling
Positive contact indication
neutral protection setting
Without protection
earth-leakage protection
Without
height
130 mm
width
100 mm
depth
60 mm

99,999.00