Weight | 0.5 kg |
---|
BG Electrical 2.1 A USB Charger and Wi-Fi Range Extender Plug Socket 822UWR
- Improved Wi-Fi coverage throughout your home
- Works with all wireless broadband routers
- Easy to install and setup with one-touch WPS (Wi-Fi Protected Setup)
- Perfect for streaming music and videos or playing online games
- Suitable for computers, tablets, mobile phones, games consoles, TVs
- No plug-in adapters – keep your sockets free for use
- Wireless 2.4GHz single band
- Retrofits a standard 25mm wall box
- N300 – 300Mbps speed 802.11b/g/n wireless
- Terminal capacity; 3 x 2.5mmΒ², 3 x 4.0mmΒ² or 2 x 6mmΒ²
- Twin earth fitted as standard to allow a double earth facility for installations requiring high integrity protective connection Ref. BS 7671:2008
- Manufactured to BS 1363-2
- Supplied with 2 x 32mm screws and screw covers
- 86mm x 146mm x 10mm (front plate) (H x W x D)
₦28,500.00
CompareBased on 0 reviews
Be the first to review “BG Electrical 2.1 A USB Charger and Wi-Fi Range Extender Plug Socket 822UWR”
-
Schneider Circuit Breakers, SCHNEIDER SECTIONS
Miniature circuit-breaker, Acti9 iC60H, 2P, 63 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2) A9F84263
Schneider Circuit Breakers, SCHNEIDER SECTIONSMiniature circuit-breaker, Acti9 iC60H, 2P, 63 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2) A9F84263
Main device application Distributionrange Acti 9product name Acti 9 iC60product or component type Miniature circuit-breakerdevice short name IC60Hpoles description 2Pnumber of protected poles 2[In] rated current 63Β Anetwork type DC
ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000Β A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
42Β kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
10Β kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Β kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
30Β kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Β kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
42Β kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2standards IEC 60947-2
IEC 60898-1
EN 60947-2
EN 60898-1Complementary network frequency 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 15Β kA 50Β % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
7.5Β kA 50Β % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz
5Β kA 50Β % conforming to EN 60947-2 – 440 V AC 50/60 Hz
15Β kA 50Β % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7.5Β kA 50Β % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz
5Β kA 50Β % conforming to IEC 60947-2 – 440 V AC 50/60 Hz
7500Β A 75Β % conforming to EN 60898-1 – 400 V AC 50/60 Hz
7500Β A 75Β % conforming to IEC 60898-1 – 400 V AC 50/60 Hz
21Β kA 50Β % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz
21Β kA 50Β % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz
15Β kA 100Β % conforming to IEC 60947-2 – 72…125 V DC
15Β kA 100Β % conforming to EN 60947-2 – 72…125 V DC[Ui] rated insulation voltage 500Β V AC 50/60 Hz conforming to EN 60947-2
500Β V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6Β kV conforming to EN 60947-2
6Β kV conforming to IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Fixedmounting support DIN railcomb busbar and distribution block compatibility Top or bottom: YES9 mm pitches 4height 85Β mmwidth 36Β mmdepth 78.5Β mmnet weight 0.25Β kgcolour Whitemechanical durability 20000Β cycleselectrical durability 10000Β cyclesconnections – terminals Single terminal (top or bottom) 1β¦35Β mmΒ² rigid
Single terminal (top or bottom) 1β¦25Β mmΒ² flexiblewire stripping length 14Β mm for top or bottom connectiontightening torque 3.5Β N.m top or bottomearth-leakage protection Separate blockSKU: n/a -
SOLAR POWERED
Solar Panel YL270W Poly
The 60-cell polycrystalline module is currently one of the strongest in the market with 270 Wp output power. Compliant with advanced load tests – meets the load requirement of 5400 Pa. By optimizing the design of solar cells and selecting the right materials, the module achieves high efficiency even in a weaker light. Due to high corrosion resistance due to salt (fog) and ammonia, the modules are also suitable for agricultural and coastal surfaces.
Package includes:
Connection cable (L) with a width of 4.0 mm2 and a length of 900 mm; the toughened glass front has low iron content and is resistant to high temperatures; frame made of anodized aluminum alloy.
SKU: n/a -
LIGHT SWITCHES & ELECTRICAL SOCKETS
20A 250V 1 Gang Double Pole Switch with Neon and Earth KB31D20NE
Main range Vivaceproduct or component type Switchdevice short name KB31device presentation Complete mechanismComplementary switch function Double 1-way with earthactuator Rockerpilot light Neon indicator lampnumber of gangs 1 gangcolour tint Whitematerial Polycarbonate: grid plate
Polycarbonate: surround
Polycarbonate: baseprojecting depth 8Β mmdevice mounting Flushmounting support Wall mountedfixing mode By screw M3.5fixing center 60.3 mmembedding depth 35Β mmrated current 20 A at 250 V AC, inductive[Ue] rated operational voltage 250 V ACnetwork frequency 50 Hzcontacts material Brass and phosphor bronzeconnections – terminals pillar terminalterminal identifier L2
N2
N1
L1tightening torque 0.4Β N.mclamping connection capacity 2.5 mmΒ²
4 mmΒ²width 87Β mmheight 87Β mmSKU: n/a -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
Easy9 miniature circuit breaker- 4P – 32 A – C curve – 6000 A – 400 V EZ9F56432
Schneider Circuit Breakers, SCHNEIDER SECTIONSEasy9 miniature circuit breaker- 4P – 32 A – C curve – 6000 A – 400 V EZ9F56432
Main range Easy9device application Distributionproduct or component type Miniature circuit-breakerdevice short name Easy9 MCBPoles 4Pnumber of protected poles 4[In] rated current 32Β Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000Β A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1
6000Β A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1suitability for isolation Yes conforming to IEC 60898-1Complementary network frequency 50 Hz[Ue] rated operational voltage 220 V AC 50/60 Hz
400 V AC 50/60 Hzmagnetic tripping limit 5…10 x In[Ics] rated service breaking capacity 6Β kA 100Β % x Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1[Ui] rated insulation voltage 500Β V AC 50/60 Hz conforming to IEC 60898-1[Uimp] rated impulse withstand voltage 4Β kV conforming to IEC 60898-1contact position indicator Yescontrol type Togglelocal signalling Withoutmounting mode Clip-onmounting support DIN rail9 mm pitches 8height 81Β mmwidth 72Β mmdepth 66.5Β mmcolour Grey (RAL 7035)mechanical durability 10000Β cycleselectrical durability 4000Β cyclesconnections – terminals Tunnel type terminal (top or bottom) 1β¦25Β mmΒ² flexible
Tunnel type terminal (top or bottom) 1β¦35Β mmΒ² rigidtightening torque 3.5Β N.m top or bottomSKU: n/a -
ELECTRICAL INDUSTRIAL, TRANSFORMER
MEKSAN Transformer 200kVA 11/415kV
Meksan Transformer manufactureΒ distribution and power transformer from 50 kVA up to 50 MVA.Β Β Our products are produced in accordance with theΒ TS 267Β and theΒ IEC60076Β Β standards. Our production is documented with theΒ TSEΒ (TΓΌrkish Standard Institue) standards confortmity,Β ISO 9001:2000Β quality system andΒ ISO 14001Β environmental management system certificates.
SKU: n/a