Three Phase(TPN) 4, 6, 8 & 12Ways
MCB Protected Socket: Single Pole, Two Pole, Three Pole, Four Pole, SPN, TPN 10Amp, 15Amp, 20Amp, 32Amp, 40Amp, 50Amp, 63Amp, 80Amp, 100Amp,125Amp,200Amp etc
Havells 12 Way 100A Three Phase(TPN) Distribution Board C/W MCB
Features
Compact DBs which occupy minimum space
Raised neutral link for easy wiring
Suitable for surface & fush mounting
Detachable din bar with end stoppers for easy assembly of breakers
Supplied with fully shielded bus-bars
Level marks for providing indication for fitment in wall
Supplied with neutral & earth link, top & bottom detachable plates
Supplied with masking sheet to protect components from cement during plastering
₦89,500.00
Based on 0 reviews
Be the first to review “Havells 12 Way 100A Three Phase(TPN) Distribution Board C/W MCB”
Vendor Information
- Address:
- No ratings found yet!
-
CABLE AND CABLE MANAGEMENT, Electro, SINGLE CORE WIRE
Cutix 16mm Single Core Copper Wire
Our cables with PVC (Polyvinyl Chloride) sheathing are used in a vast number of applications from fixed wiring to flexible installations and they are available in various sizes, colours and number of conductors.
SKU: 338 -
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
ABB MCB Switch 3 POLE
Trip Free mechanism10KA short circuit breaking capacity for B and C Low power consumption,thus cost effective and energy savingFinger safe terminal IP20 degree of protectionDual Terminal Facility15 Plate Arc chute for effective arc quenchingsilver graphite contacts for enhance lifeAccessories switchPerformance and safetyPositive contact indicatorReliability and continuity of serviceSuitable for both DESB and switch boardShort Circuit breaking capacity 3KA MCBProtection against overload and short Circuit breaking capacity 3KA
SKU: 284 -
CIRCUIT BREAKERS
TeSys Schneider Electric Overload Relays 4-6amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.SKU: Overload1 -