PvC insulated flame retardant cables are fixed laid in the circuit with frequency 50Hz and voltage up to 0.6/1KV running from the main breaker panel or fuse box outlets to provide reliable, high-quality electrical current for your residential installations with our range of 100% pure copper wire from top brands like Nigerchin, Coleman, Kablemetal Our wires and cables with PVC (Polyvinyl Chloride) sheathing are used also in a vast number of applications from fixed wiring to flexible installations and they are available in various core (single core, two core, three core),sizes(mm), colors and comes in full 100 metres/yards in length. We also have Fire Resistance(FR) and Fire Resistance Low Smoke cable (FRLS).
KABLEMETAL 1.5mm Single Core – Black
We offer other range of products across various categories and sub categories and our services are Procurement, installation and Management etc of electrical products, should you have any inquiry we are always here to do our best to promptly answer you.
₦39,200.00
CompareWeight | 2 kg |
---|
Based on 0 reviews
Be the first to review “KABLEMETAL 1.5mm Single Core – Black”
-
Electro, LED LIGHTS, LIGHTING, OUTDOOR LIGHTS
PHILIP CANOPY LIGHT BBP500 G2 LED125/NW PSU S-WB 90W Philips
Electro, LED LIGHTS, LIGHTING, OUTDOOR LIGHTSPHILIP CANOPY LIGHT BBP500 G2 LED125/NW PSU S-WB 90W Philips
Specifications
- General Information
-
Beam angle of light source – °Light source color 840 neutral whiteLight source replaceable NoNumber of gear units 1 unitDriver/power unit/transformer Power supply unitDriver included YesOptic type Wide beamOptical cover/lens type Tempered glassLuminaire light beam spread 110°Control interface –Connection Flying leads/wiresCable Cable 0.3 m without plugProtection class IEC Safety class IGlow-wire test Temperature 650 °C, duration 5 sFlammability mark For mounting on normally flammable surfacesCE mark CE markENEC mark –Warranty period 3 yearsConstant light output NoNumber of products on MCB of 16 A type B 4EU RoHS compliant NoLight source engine type LED - Operating and Electrical
-
Input Voltage 220 to 240 VInput Frequency 50 to 60 HzInrush current 46 AInrush time 440 msPower Factor (Min) 0.95 - Controls and Dimming
-
Dimmable No - Mechanical and Housing
-
Housing Material Aluminum die castReflector material –Optic material PolycarbonateOptical cover/lens material Tempered glassFixation material –Optical cover/lens finish ClearOverall length 400 mmOverall width 400 mmColor White - Approval and Application
-
Ingress protection code IP65 [ Dust penetration-protected, jet-proof]Mech. impact protection code IK07 [ 2 J reinforced] - Initial Performance (IEC Compliant)
-
Initial luminous flux (system flux) 12500 lmLuminous flux tolerance +/-10%Initial LED luminaire efficacy 139 lm/WInit. Corr. Color Temperature 4000 KInit. Color Rendering Index >80Initial chromaticity (0.38.0.38)SDCM<5Initial input power 90 WPower consumption tolerance +/-10% - Over Time Performance (IEC Compliant)
-
Median useful life L70B50 50000 hMedian useful life L80B50 40000 hMedian useful life L90B50 30000 h - Application Conditions
-
Ambient temperature range -40 to +45 °CMaximum dim level Not applicableSuitable for random switching No - Product Data
-
Full product code 911401538751Order product name BBP500 G2 LED125/NW PSU S-WBOrder code 911401538751Numerator – Quantity Per Pack 1Numerator – Packs per outer box 1Material Nr. (12NC) 911401538751Net Weight (Piece) 6.099 kg
SKU: n/a -
CHINT
NX8 – MCB CHINT . ELECTRIC BOX 5way
Material: ABS/PC Plastic
Type: Wall-mounted electrical cabinet
Degree of protection: IP30
Meets standard: IEC/EN 60439-3 (IEC/EN 60670-24)The MCB CHINT NX8 plastic electrical cabinet box is compact, sturdy, and has a high finish.
Can be used as a wall cabinet or used as a floating cabinet due to its versatile design. There are error lights, power failure.
ABS plastic helps to withstand factors such as heat, sunlight, increasing the life of the cabinet. The lid of the cabinet is made of transparent PC plastic, making it easy to see the equipment inside. Available with 4-sided wiring hole.
Standard DIN Rail, convenient to connect and install equipment
Parameters of MCB CHINT NX8 . plastic electrical cabinet box
- Material: ABS/PC . plastic
- Type: Wall mounted plastic electrical cabinet
- Protection level: IP30
- Meets standards: IEC/EN 60439-3 (IEC/EN 60670-24)
- Application: in civil electricity, industrial electricity, solar power
SKU: n/a -
FLUORESENT TUBES, LIGHTING
Philip Pacific TCW216 2XTL5-28W HFS PI Philips
Pacific TCW216 is a functional dust-, jet-, shock- and vandalproof luminaire, and can accommodate both TL-D and TL5 (16 mm) fluorescent lamps. The cover is fixed to the housing by means of an innovative concept using integrated fixing points to avoid external lockers. There is a choice of different standard versions available. The
luminaire can be mounted individually or in-line with easy ‘click’ installation. Flexibility is ensured with a choice of fixing points and different cable entries. The TCW216 can also be suspended from Philips TTX410 light-line systems.SKU: n/a -
CABLE AND CABLE MANAGEMENT, Electro, SINGLE CORE WIRE
KABLEMETAL 2.5mm Single Core – Red
We offer other range of products across various categories and sub categories and our services are Procurement, installation and Management etc of electrical products, should you have any inquiry we are always here to do our best to promptly answer you.
SKU: 399 -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
Miniature circuit-breaker, Acti9 iC60H, 1P, 6 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2) A9F84106
Schneider Circuit Breakers, SCHNEIDER SECTIONSMiniature circuit-breaker, Acti9 iC60H, 1P, 6 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2) A9F84106
Main device application Distributionrange Acti 9product name Acti 9 iC60product or component type Miniature circuit-breakerdevice short name IC60Hpoles description 1Pnumber of protected poles 1[In] rated current 6 Anetwork type AC
DCtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
15 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
42 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
30 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
15 kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
20 kA Icu at 12…60 V DC conforming to EN/IEC 60947-2utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2standards EN 60898-1
IEC 60947-2
IEC 60898-1
EN 60947-2Complementary network frequency 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 21 kA 50 % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz
7.5 kA 50 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
21 kA 50 % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz
7.5 kA 50 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7500 A 75 % conforming to EN 60898-1 – 230 V AC 50/60 Hz
7500 A 75 % conforming to IEC 60898-1 – 230 V AC 50/60 Hz
15 kA 50 % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz
15 kA 50 % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz
15 kA 100 % conforming to EN 60947-2 – 72 V DC
15 kA 100 % conforming to IEC 60947-2 – 72 V DC
20 kA 100 % conforming to EN 60947-2 – 12…60 V DC
20 kA 100 % conforming to IEC 60947-2 – 12…60 V DClimitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Fixedmounting support DIN railcomb busbar and distribution block compatibility Top or bottom: YES9 mm pitches 2height 85 mmwidth 18 mmdepth 78.5 mmnet weight 0.215 kgcolour Whitemechanical durability 20000 cycleselectrical durability 10000 cyclesconnections – terminals Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexiblewire stripping length 14 mm for top or bottom connectiontightening torque 2 N.m top or bottomearth-leakage protection WithoutSKU: n/a
There are no reviews yet.