Solar Panel YL275W Poly
The 60-cell polycrystalline module is currently one of the strongest in the market with 270 Wp output power. Compliant with advanced load tests – meets the load requirement of 5400 Pa. By optimizing the design of solar cells and selecting the right materials, the module achieves high efficiency even in a weaker light. Due to high corrosion resistance due to salt (fog) and ammonia, the modules are also suitable for agricultural and coastal surfaces.
Package includes:
Connection cable (L) with a width of 4.0 mm2 and a length of 900 mm; the toughened glass front has low iron content and is resistant to high temperatures; frame made of anodized aluminum alloy.
₦39,500.00
Vendor Information
- Vendor: Electric Mall
- 5.00 rating from 1 review
- ACCESSORIES, ELECTRICAL FITTINGS, SOCKETS, SOCKETS & SWITCHES
BG ELECTRICAL 855RCD 13A RCD FUSED CONNECTION UNIT
ACCESSORIES, ELECTRICAL FITTINGS, SOCKETS, SOCKETS & SWITCHESBG ELECTRICAL 855RCD 13A RCD FUSED CONNECTION UNIT
BG Electrical 855RCD 13A RCD Fused Connection Unit
Features
- Maximum load 3120 watts 240V AC
- 30 mA trip speed 40 ms
- Latching type
- Terminal capacity 3 x 2.5mm², 2 x 4.0mm² & 1 x 6.0mm²
- Manufactured to BS 7288:1990
- 855RCD – Minimum mounting box depth 35mm
- 10mm Spacer provded for shallow boxes
SKU: n/a - CABLE AND CABLE MANAGEMENT, SINGLE CORE WIRE
Berliac 25mm single PVC
single-core cables are manufactured according to BS-6004/NIS-172 standards and can be installed in conduit, in cable trunking and in cable ducting or where there is deemed little risk of mechanical damage. These cables can be clipped direct, on cable tray, embedded or in free air. These cables are not intended to be laid underground.
Construction:
Conductors: Solid or stranded plain annealed copper wire (class 1 or class 2) to BS, EN 60228.
Insulation: PVC
Sheath: PVC
Voltage rating (U0/U) 300/500V
Conductor temp 70°C
Min, bending radius 4 x overall diameter of cable.
SKU: n/a - FLEXIBLE WIRE
Berliac 2.5mm x 2core PVC/PVC flexible cable
This has a high conductivity bunched plain annealed flexible copper conductors, insulated in a parallel configuration with a flexible grade PVC and a colour stripe on each core for polarity indication. Specification for our flexible cables conforms to BS 7919/IEC – 60502 at voltage rating 300V/500V.
SKU: n/a - CABLE AND CABLE MANAGEMENT, SINGLE CORE WIRE
Berliac 16mm single PVC
single-core cables are manufactured according to BS-6004/NIS-172 standards and can be installed in conduit, in cable trunking and in cable ducting or where there is deemed little risk of mechanical damage. These cables can be clipped direct, on cable tray, embedded or in free air. These cables are not intended to be laid underground.
Construction:
Conductors: Solid or stranded plain annealed copper wire (class 1 or class 2) to BS, EN 60228.
Insulation: PVC
Sheath: PVC
Voltage rating (U0/U) 300/500V
Conductor temp 70°C
Min, bending radius 4 x overall diameter of cable.
SKU: n/a - TRANSFORMER
BETA 1000KVA/11/0.415V COPPER/COPPER WINDING TRANSFORMER
Produced within a power range between 10 – 100.000 kVA , up to 170 kV high voltage level, three phase or single phase, oil immersed, ONAN, ONAF, OFWF, with Off-Load or On-Load Tap Changer, used both external and internal.
Dimensions of transformer conservator are determined and designed after several heat calculations of the oil stored in expansion tank and oil level changes by heat.
Being open to atmosphere, oil pressure changes continuously in Conservator Type Transformers due to thermal effects and exchange of air is dehumidified via air breather silicagel.SKU: n/a
There are no reviews yet.