Metallic Delta Cable ladders are manufactured for the smooth and easy pulling of cable from one point to another. We have designed the best cable ladders, by taking care of cable loads and practical site problems. The rungs are heavy duty strut channels which provides a heavy support to the cables even in wider ladders. Delta Cable ladders is having maximum cable loading depth by fixing rungs at the lowest point of side rails. Spacings of rungs are done in such a way that it enables the dropping of any large diameter cables.
Trans Delta 600 X 150 X 3mtrs Cable Ladders
₦0.00
CompareBased on 0 reviews
Be the first to review “Trans Delta 600 X 150 X 3mtrs Cable Ladders”
-
LED DRIVERS
Philips Xitanium 50W 230V LED DRIVER Philip
Eco passport – Our environmental product specifications overview
Philips cares about the environment and society at large, and strongly supports eco-design of products.Specifications
General Characteristics:
Housing – [Not Specified]
Lifetime – 50000 hr
Input Frequency – 50/60 Hz
Relative Humidity – 10 (min), 90 (max) %
IP Classification – 20
Lifetime 90% surv.@Tcaselife – 50000 hr
System Description – TD/TE [Touch&DALI/Trailing edge dimming]
Number of LEDs – xOperating Characteristics
12V output – Yes
Ripple current – 20 %
Efficiency Range – 88-90 %
Power Factor Range – 0.9
Output Power Range – 15-50 W
Power Factor (100% load) – 0.9 (min) –
Output Voltage Range – 31-62 V
Output Current Range (mA) – 300-1000
Dimming range – 100-10 %
Dimmable – Yes
Input Voltage Range (DC) – 186-250 V
Inrush Current Peak – 48 (max) A
Output Current Tolerance – -5 (min), 5 (max) %
Inrush Current Width to 50% – 180 us
Type of Dimming – Touch&DALI and trailing edge
Input Voltage Range (AC) – 220-240 V
Earth leakage current – 0.7 (max) mA
Max drivers on MCB(16A type-B) – 12 (max) x
Control input protection – Yes (Basic insulation)Wiring Characteristics
Connection on driver to L2 – JST connector
Hot wiring – Yes
Connector type input terminal – Wago 250
Connector type output terminal – Wago 250Product Dimensions
Length A1 – 140.0 mm
Width B1 – 75 mm
Height C1 – 32 mm
Fixing Hole Diameter D1 – 4.5 mm
Fixing Hole Distance Width B2 – 63.7 mm
Fixing Hole Distance Length A2 – 128.5 mmSKU: Philip Driver1 -
ELECTRICAL INDUSTRIAL, Electro, WIRE CABLE TRAY & CABLE LADDER
100mm x 50mm Foreign Wire Merge Cable Tray By 3 Meter
ELECTRICAL INDUSTRIAL, Electro, WIRE CABLE TRAY & CABLE LADDER100mm x 50mm Foreign Wire Merge Cable Tray By 3 Meter
Cable tray are the most common solution for supporting and routing of cables in an installation.
For this reason, cable tray are available in a variety of sizes and standards, in order to cover the
wide range of applications.Embedded perforations for :
– extra load capacity
– better aeration
– better stability
– better condensation drainage
-50x300mmAlternative perforations for :
– better fixation on the supports
– very useful for cable fixation
-Standard finish GalvanizedSKU: WireM2 -
CIRCUIT BREAKERS
TeSys Schneider Electric Overload Relays 4-6amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.SKU: Overload1