AVS13
- Protection against:
- High voltage
- Low voltage
- Spikes/surges
- Powerback surges
- Ideal for:
- All electrical and electronic equipment
- Max current: 13 amps
- Wait time: User adjustable from 10 seconds to 3 minutes
Protect against
Ideal for
Max current: 13 amps
Wait time: User adjustable from 10 seconds to 3 minutes
₦26,000.00
CompareA 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 100-250 V, AC/DC
range of product |
EasyPact
|
|
---|---|---|
product or component type |
Circuit breaker
|
|
device short name |
Easypact EZC100N
|
|
circuit breaker name |
Easypact EZC100N
|
|
device application |
Distribution
|
|
poles description |
4P
|
|
protected poles description |
3t
|
|
network type |
AC
DC |
|
network frequency |
50/60 Hz
|
|
[In] rated current |
100 A at 40 °C
|
|
[Ui] rated insulation voltage |
690 V AC 50/60 Hz conforming to IEC 60947-2
|
|
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947-2
|
|
[Ue] rated operational voltage |
550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2 |
|
breaking capacity code |
N
|
|
breaking capacity |
10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380…400 V AC 50/60 Hz conforming to IEC 60947-2 |
|
[Ics] rated service breaking capacity |
5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110…130 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380…400 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 |
|
suitability for isolation |
Yes conforming to IEC 60947-2
|
|
utilisation category |
Category A
|
|
trip unit name |
TM-D
|
|
trip unit technology |
Thermal-magnetic
|
|
trip unit rating |
30 A at 50 °C
|
|
protection type |
Overload protection
Short-circuit protection |
|
pollution degree |
3 conforming to IEC 60947
|
control type |
Toggle
|
|
---|---|---|
mounting mode |
Fixed
|
|
mounting support |
Backplate
|
|
upside connection |
Front
|
|
downside connection |
Front
|
|
mechanical durability |
8500 cycles
|
|
electrical durability |
Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
|
|
connection pitch |
25 mm
|
|
local signalling |
Positive contact indication
|
|
neutral protection setting |
Without protection
|
|
earth-leakage protection |
Without
|
|
height |
130 mm
|
|
width |
100 mm
|
|
depth |
60 mm
|
Product benefits
− Streets
− Road lighting
− Car parks
− Mast adapter with adjustable tilt angle
− High transparence cover made of ultra white tempered glass
− Homogeneous luminance distribution and minimized glare thanks to optical lense
− Maintenance comfort thanks to module assembly concept
− High quality aluminum housing
Product features
− Surge protection: up to 10 kV (L-N)
Lifetime(L70): up to 50,000 h (temperature at t − a = 50 °C)
− Type of protection: IP66
− Impact resistance: IK08
− High luminous efficacy: up to 120 lm/W
YTO Diesel Engine Co Ltd specializes in the design and manufacture of diesel generator engines since 1958. YTO has formed international partnerships with world leaders in their respective fields to maintain the latest technologies in their engines and produce a reliable, world-class product. The YTO engines are used internationally in offroad vehicles, tractors, construction machinery, agriculture, combine harvesters and more. The engines are high quality and reliability with a solid history in Africa. These engines include high temperature and low oil, water and fuel protection to protect against engine damage. Generator World is the sole-authorized distributor for YTO Engines in Sub Saharan Africa.
YTO engines are ideal for customers who require reliable performance and reliable power and cover a range of sizes from 10kva- 630kva whether you need prime or standby power- YTO is ready to match your power needs and provide a reliable source of power to ensure your productivity is not impacted. Whether you need a diesel generator for commercial or industrial use, these gensets are the perfect fit for the budget conscious consumer looking for standby power. By choosing one of these generators, you will still enjoy the same build quality and components youʼve come to expect from Generator World.
(2years Warranty of all the component, except the Main Alternator)
Lamp family code |
–
|
Light source color |
740 neutral white
|
Light source replaceable |
No
|
Number of gear units |
1 unit
|
Driver/power unit/transformer |
Power supply unit
|
Driver included |
Yes
|
Optical cover/lens type |
–
|
Control interface |
–
|
Connection |
–
|
Cable |
–
|
Protection class IEC |
Safety class I
|
Flammability mark |
For mounting on normally flammable surfaces
|
CE mark |
CE mark
|
ENEC mark |
–
|
Warranty period |
3 years
|
Optic type outdoor |
–
|
Constant light output |
No
|
Number of products on MCB of 16 A type B |
11
|
Light source engine type |
LED
|
Upward light output ratio |
0
|
Standard tilt angle posttop |
–
|
Standard tilt angle side entry |
0°
|
Input Voltage |
220 to 240 V
|
Input Frequency |
50 to 60 Hz
|
Inrush current |
46 A
|
Inrush time |
0.44 ms
|
Power Factor (Min) |
0.9
|
Dimmable |
No
|
Housing Material |
Aluminum die cast
|
Optic material |
Polycarbonate
|
Optical cover/lens material |
Polycarbonate
|
Fixation material |
Aluminum
|
Mounting device |
Side-entry for diameter 42 to 60 mm
|
Optical cover/lens shape |
Ball, globular
|
Optical cover/lens finish |
–
|
Overall length |
492 mm
|
Overall width |
295 mm
|
Overall height |
86 mm
|
Effective projected area |
0.14 m²
|
Color |
Gray
|
Ingress protection code |
IP66 [ Dust penetration-protected, jet-proof]
|
Mech. impact protection code |
IK08 [ 5 J vandal-protected]
|
Initial luminous flux (system flux) |
14400 lm
|
Luminous flux tolerance |
+/-5%
|
Initial LED luminaire efficacy |
120 lm/W
|
Init. Corr. Color Temperature |
4000 K
|
Init. Color Rendering Index |
>70
|
Initial chromaticity |
(0.43, 0.40) SDCM < 5
|
Initial input power |
120 W
|
Power consumption tolerance |
+/-5%
|
Median useful life L70B50 |
100000 h
|
Ambient temperature range |
-30 to +50 °C
|
Maximum dim level |
Not applicable
|
Full product code |
911401816498
|
Order product name |
BRP392 LED144/NW 120W 220-240V DM
|
Order code |
911401816498
|
Numerator – Quantity Per Pack |
1
|
Numerator – Packs per outer box |
1
|
Material Nr. (12NC) |
911401816498
|
Net Weight (Piece) |