MANUFACTURED FROM PURE ELECTROLYTIC COPPER.
COPPER LUGS & CABLE TERMINALS FROM 2.5 TO 1000 MM2 WITH DIFFERENT STUD HOLE SIZES AS REQUIRED .
LEAD FREE ELECTRO TIN PLATED TO PREVENT ATMOSPHERIC CORROSION.
CABLE LUGS ARE FULLY ANNEALED TO GUARANTEE OPTIMUM DUCTILITY.
UL, CUL CERTIFIED PRODUCT.
Copper Compression Cable Lugs Heavy Duty
Copper SC 16-10 – 10 Pcs
MANUFACTURED FROM PURE ELECTROLYTIC COPPER.
COPPER LUGS & CABLE TERMINALS FROM 2.5 TO 1000 MM2 WITH DIFFERENT STUD HOLE SIZES AS REQUIRED .
LEAD FREE ELECTRO TIN PLATED TO PREVENT ATMOSPHERIC CORROSION.
CABLE LUGS ARE FULLY ANNEALED TO GUARANTEE OPTIMUM DUCTILITY.
UL, CUL CERTIFIED PRODUCT.
₦3,000.00
CompareWeight | 0.6 kg |
---|
Based on 0 reviews
Be the first to review “Copper Compression Cable Lugs Heavy Duty”
-
Electro, LIGHT SWITCHES & ELECTRICAL SOCKETS
1 Gang Blank Plate KB30
Main product or component type Cover framedevice short name KB30Complementary number of gangs 1 gangColour tint Whitematerial Polycarbonate: grid plate
Polycarbonate: surroundprojecting depth 8Ā mmdevice mounting Flushwidth 86Ā mmheight 86Ā mmSKU: n/a -
Low Voltage Products and Systems, SCHNEIDER SECTIONS
EZC100N4030 – Circuit breaker Easypact EZC100N – TMD – 30 A – 4 poles 3d
Low Voltage Products and Systems, SCHNEIDER SECTIONSEZC100N4030 – Circuit breaker Easypact EZC100N – TMD – 30 A – 4 poles 3d
Main range of product EasyPactproduct or component type Circuit breakerdevice short name Easypact EZC100Ncircuit breaker name Easypact EZC100Ndevice application Distributionpoles description 4Pprotected poles description 3tnetwork type AC
DCnetwork frequency 50/60 Hz[In] rated current 100Ā A at 40Ā Ā°C[Ui] rated insulation voltage 690Ā V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6Ā kV conforming to IEC 60947-2[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2breaking capacity code Nbreaking capacity 10Ā kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25Ā kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
25Ā kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
5Ā kA Icu at 125 V DC 1P conforming to IEC 60947-2
5Ā kA Icu at 250 V DC 2P conforming to IEC 60947-2
5Ā kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
15Ā kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
18Ā kA Icu at 380…400 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service breaking capacity 5Ā kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
2.5Ā kA at 125 V DC conforming to IEC 60947-2
2.5Ā kA at 250 V DC conforming to IEC 60947-2
2.5Ā kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
12.5Ā kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
12.5Ā kA at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
9Ā kA at 380…400 V AC 50/60 Hz conforming to IEC 60947-2
7.5Ā kA at 415 V AC 50/60 Hz conforming to IEC 60947-2suitability for isolation Yes conforming to IEC 60947-2utilisation category Category Atrip unit name TM-Dtrip unit technology Thermal-magnetictrip unit rating 30Ā A at 50Ā Ā°Cprotection type Overload protection
Short-circuit protectionpollution degree 3 conforming to IEC 60947Complementary control type Togglemounting mode Fixedmounting support Backplateupside connection Frontdownside connection Frontmechanical durability 8500Ā cycleselectrical durability Category A: 1500Ā cycles 415 V AC 50/60 Hz conforming to IEC 60947-2connection pitch 25Ā mmlocal signalling Positive contact indicationneutral protection setting Without protectionearth-leakage protection Withoutheight 130Ā mmwidth 100Ā mmdepth 60Ā mmSKU: n/a -
ACCESSORIES
BLUEGATE 4000VA UPS
The Blue Gate UPS range is in wide use and rated high by consumers as a reliable brand in the Nigerian market. Its high performance rating has made the Bluegate UPS a choice option whether for office or home power backup applications.
Line interactive design with higher efficiency
Fully digitized microprocessor control
High perfroamnce SMD technology
Wide input voltage & frequency range
Boost & buck AVR
3 LED indicators for monitoring
Lightening & surge protection
Short circuit & overload protection
Energy saving function with UPS green mode
Automatically charging in UPS off mode
Automatically self-detection when start-up
Auto restart while AC recovery
Intelligent battery management
RJ45, USB (optional)SKU: 4000VA -
-
LIGHT SWITCHES & ELECTRICAL SOCKETS, SCHNEIDER SECTIONS
Universal Shaver Unit, Horizontal, White E84T727H_WE
LIGHT SWITCHES & ELECTRICAL SOCKETS, SCHNEIDER SECTIONSUniversal Shaver Unit, Horizontal, White E84T727H_WE
Main range ZENceloproduct or component type Shaver socketinstallation direction Horizontalinput voltage 240 V AC 50 Hzoutput voltage 115 V AC 50 Hz
240 V AC 50 Hzmaterial Polycarbonate: base
Polycarbonate: grid plate
Polycarbonate: surroundcolour tint WhiteComplementary device mounting Surface
Flushcable cross section 1ā¦2.5Ā mmĀ²rated operational power in VA 20Ā VAconnections – terminals Pillar terminal without pressure plateelectrical insulation class Class Bwidth 147Ā mmheight 87Ā mmdepth 49.3Ā mmSKU: n/a
There are no reviews yet.