The D–Light LED wall-light features either a brushed aluminium or white finish. This product is IP20 rated.
Based on 0 reviews
Be the first to review “D-LIGHT”
-
Electro, ENERGY SAVING BULBS, FLUORESENT TUBES, LIGHT BULBS, LIGHTING
OSRAM DULUX D 13/840
Product features
Average life: 10,000 h
Color rendering index Ra: 80…89
Short and compact pin-base lamp with double-turn tubes
Single-ended two-pin plug-in G24d baseProduct benefits
Extremly economical
Good quality of light
Excellent luminous flux
Long service life
Improved maintenanceAreas of application
Offices, public buildings
Shops
Supermarkets and department stores
Hotels, restaurants
IndustryEquipment / Accessories
Suitable for operation on conventional control gearSKU: OSRAM DULUX D -
LED DRIVERS
Philips Xitanium 50W 230V LED DRIVER Philip
Eco passport – Our environmental product specifications overview
Philips cares about the environment and society at large, and strongly supports eco-design of products.Specifications
General Characteristics:
Housing – [Not Specified]
Lifetime – 50000 hr
Input Frequency – 50/60 Hz
Relative Humidity – 10 (min), 90 (max) %
IP Classification – 20
Lifetime 90% surv.@Tcaselife – 50000 hr
System Description – TD/TE [Touch&DALI/Trailing edge dimming]
Number of LEDs – xOperating Characteristics
12V output – Yes
Ripple current – 20 %
Efficiency Range – 88-90 %
Power Factor Range – 0.9
Output Power Range – 15-50 W
Power Factor (100% load) – 0.9 (min) –
Output Voltage Range – 31-62 V
Output Current Range (mA) – 300-1000
Dimming range – 100-10 %
Dimmable – Yes
Input Voltage Range (DC) – 186-250 V
Inrush Current Peak – 48 (max) A
Output Current Tolerance – -5 (min), 5 (max) %
Inrush Current Width to 50% – 180 us
Type of Dimming – Touch&DALI and trailing edge
Input Voltage Range (AC) – 220-240 V
Earth leakage current – 0.7 (max) mA
Max drivers on MCB(16A type-B) – 12 (max) x
Control input protection – Yes (Basic insulation)Wiring Characteristics
Connection on driver to L2 – JST connector
Hot wiring – Yes
Connector type input terminal – Wago 250
Connector type output terminal – Wago 250Product Dimensions
Length A1 – 140.0 mm
Width B1 – 75 mm
Height C1 – 32 mm
Fixing Hole Diameter D1 – 4.5 mm
Fixing Hole Distance Width B2 – 63.7 mm
Fixing Hole Distance Length A2 – 128.5 mmSKU: Philip Driver1 -
CIRCUIT BREAKERS
TeSys Schneider Electric Overload Relays 1.6 – 2.5amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.SKU: Overload3 -
ARMOURED CABLE, ELECTRICAL INDUSTRIAL, Electro
35mm 4Core Amroured Cable|Per Meter (Nigerchin Cable and Wire)
ARMOURED CABLE, ELECTRICAL INDUSTRIAL, Electro35mm 4Core Amroured Cable|Per Meter (Nigerchin Cable and Wire)
35mm 4 Core Armoured Cable is a variant of electrical cable that is commonly found within powered networks as well as supplying mains voltage to multiple powered devices etc. It is used in a wide variety of electrical applications but at this size, it is commonly found within industrial compounds such as power stations and building sites.
This cable is identified by the following method of construction;
– Plain Annealed Stranded Copper for the cores/conductors
– XLPE (Cross-Linked Polyethylene) for the insulation
– PVC (Polyvinyl Chloride) for the sheathing and bedding
– Steel Wire for the armouring that protects the insulating layers beneath.
As well as a form of mechanical protection, therefore suitable for outdoor use and underground installations, the steel wire armour also acts a CPC (Circuit Protective Conductor), meaning it acts as a natural earth for the cable therefore an earth core or seperate length of earth cable is not required.
– No. of cores / size of cable – 4
– Approx overall diameter – 28.8mm
– Approx weight (m) – 2.3Kg
– Conductors – Plain Annealed Stranded Copper
– Insulation – Cross-Linked Polyethylene
– Bedding – Polyvinyl Chloride
– Armour / Protection – Steel Wire
– Sheath / Jacket – Polyvinyl Chloride
– Application – Used within large powered networks & for providing mains electricity to multiple powered devices.
– Voltage Rating – 600/1000VtSKU: 35mmnigerchin -
Electro, ENERGY SAVING BULBS, LIGHT BULBS, LIGHTING
Torch E27(Screw) 18W Energy Saving Bulb
Specifications:
• Optional wattage: 7-105W
• Operating voltage: 110 to 130V or 220 to 240V
• Frequency: 50/60Hz
• Average lifetime: 6000hrs/8000 hrs/10000hrs available
• Optional base: E27/B22/E14
• Optional Color Temperature: 2,700K/4,100K/6,500KApplications:
Shopping malls, table lamps, pendent lamps, supermarkets, restaurants, shops, hotels etc.SKU: 868
There are no reviews yet.