Lisse – White moulded – blank plate – 1 gang – matt white GGBL8010
range |
Lisse
|
|
---|---|---|
aesthetic name |
White moulded
|
|
product or component type |
Blank plate
|
|
device presentation |
Complete product
|
|
colour tint |
White
|
|
quantity per set |
Set of 10
|
fixing mode |
By screws
|
|
---|---|---|
number of gangs |
1 gang
|
|
material |
Urea (carbamide)
|
|
surface finish |
Matt
|
|
type of packing |
Carton
|
|
height |
87Ā mm
|
|
width |
87Ā mm
|
|
depth |
9Ā mm
|
|
net weight |
0.041Ā kg
|
₦2,100.00
Compare-
Schneider Circuit Breakers, SCHNEIDER SECTIONS
Miniature circuit breaker, Easy9, 3P, 10 A, C curve, 6000 A EZ9F56310
Schneider Circuit Breakers, SCHNEIDER SECTIONSMiniature circuit breaker, Easy9, 3P, 10 A, C curve, 6000 A EZ9F56310
Main range Easy9device application Distributionproduct or component type Miniature circuit-breakerdevice short name Easy9 MCBPoles 3Pnumber of protected poles 3[In] rated current 10Ā Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000Ā A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1
6000Ā A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1suitability for isolation Yes conforming to IEC 60898-1Complementary network frequency 50 Hz[Ue] rated operational voltage 220 V AC 50/60 Hz
400 V AC 50/60 Hzmagnetic tripping limit 5…10 x In[Ics] rated service breaking capacity 6Ā kA 100Ā % x Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1[Ui] rated insulation voltage 500Ā V AC 50/60 Hz conforming to IEC 60898-1[Uimp] rated impulse withstand voltage 4Ā kV conforming to IEC 60898-1contact position indicator Yescontrol type Togglelocal signalling Withoutmounting mode Clip-onmounting support DIN rail9 mm pitches 6height 81Ā mmwidth 54Ā mmdepth 66.5Ā mmcolour Grey (RAL 7035)mechanical durability 10000Ā cycleselectrical durability 4000Ā cyclesconnections – terminals Tunnel type terminal (top or bottom) 1ā¦25Ā mmĀ² rigid
Tunnel type terminal (top or bottom) 1ā¦16Ā mmĀ² flexibletightening torque 2Ā N.m top or bottomSKU: n/a -
Electro, SOCKETS & SWITCHES, SWITCHES
BG BRASS GEORGIAN LIGHT SWITCH PLATE – SINGLE 1 GANG 2 WAY
BG NBG12 Brass Georgian Light Switch Plate – Single 1 Gang 2 WayAT A GLANCE…- Top quality Brass finish – lightly lacquered to prevent finger marks
- Matching Brass rocker switch
- No visible plastic around switches
- Specification: 1 gang, 2 way, 10 amp (10AX)
- Requires a 16mm metal wall box
- Supplied with colour coded fixing screws
SKU: g7 -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
IC60H – miniature circuit breaker – 1P – 32A – C curve A9F84132
Schneider Circuit Breakers, SCHNEIDER SECTIONSIC60H – miniature circuit breaker – 1P – 32A – C curve A9F84132
Main device application Distributionrange Acti 9product name Acti 9 iC60product or component type Miniature circuit-breakerdevice short name IC60Hpoles description 1Pnumber of protected poles 1[In] rated current 32Ā Anetwork type DC
ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000Ā A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
15Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
42Ā kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
30Ā kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Ā kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
20Ā kA Icu at 12…60 V DC conforming to EN/IEC 60947-2utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2standards IEC 60947-2
IEC 60898-1
EN 60898-1
EN 60947-2Complementary network frequency 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 21Ā kA 50Ā % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
21Ā kA 50Ā % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7500Ā A 75Ā % conforming to EN 60898-1 – 230 V AC 50/60 Hz
7500Ā A 75Ā % conforming to IEC 60898-1 – 230 V AC 50/60 Hz
15Ā kA 50Ā % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz
15Ā kA 50Ā % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz
15Ā kA 100Ā % conforming to EN 60947-2 – 72 V DC
15Ā kA 100Ā % conforming to IEC 60947-2 – 72 V DC
20Ā kA 100Ā % conforming to EN 60947-2 – 12…60 V DC
20Ā kA 100Ā % conforming to IEC 60947-2 – 12…60 V DClimitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1[Ui] rated insulation voltage 500Ā V AC 50/60 Hz conforming to EN 60947-2
500Ā V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN 60947-2
6Ā kV conforming to IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Fixedmounting support DIN railcomb busbar and distribution block compatibility Top or bottom: YES9 mm pitches 2height 85Ā mmwidth 18Ā mmdepth 78.5Ā mmnet weight 0.215Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesconnections – terminals Single terminal (top or bottom) 1ā¦35Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦25Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 3.5Ā N.m top or bottomearth-leakage protection WithoutSKU: n/a -
ELECTRICAL INDUSTRIAL, TRANSFORMER
BETA 500KVA/11/0.415V COPPER/COPPER WINDING TRANSFORMER
Produced within a power range between 10 ā 100.000 kVA , up to 170 kV high voltage level, three phase or single phase, oil immersed, ONAN, ONAF, OFWF, with Off-Load or On-Load Tap Changer, used both external and internal.
Dimensions of transformer conservator are determined and designed after several heat calculations of the oil stored in expansion tank and oil level changes by heat.
Being open to atmosphere, oil pressure changes continuously in Conservator Type Transformers due to thermal effects and exchange of air is dehumidified via air breather silicagel.SKU: n/a -
Electro, SOCKETS, SOCKETS & SWITCHES
BG 2WAY DATA OUT LET – FBSRJ452
IDC Terminal connection
Easy to install, supplied with fixing screws and installation instructions
RJ45 Ethernet Socket
Screwless front plate clips on and off easily and has a sleek, flat profile
Moisture control gasket, prevents tarnishing from new plaster
Shuttered socket
ID window and colour matched shutter for each outlet
Supplied as a kit of Euro module components
Anti-fingerprint lacquer reduces unsightly fingerprints
Minimum mounting box depth 35mm
SKU: n/a -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
Miniature circuit-breaker, Acti9 iC60H, 1P, 25 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2) A9F84125
Schneider Circuit Breakers, SCHNEIDER SECTIONSMiniature circuit-breaker, Acti9 iC60H, 1P, 25 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2) A9F84125
Main device application Distributionrange Acti 9product name Acti 9 iC60product or component type Miniature circuit-breakerdevice short name IC60Hpoles description 1Pnumber of protected poles 1[In] rated current 25Ā Anetwork type DC
ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000Ā A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
15Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
42Ā kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
30Ā kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Ā kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
20Ā kA Icu at 12…60 V DC conforming to EN/IEC 60947-2utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2standards IEC 60898-1
EN 60947-2
EN 60898-1
IEC 60947-2Complementary network frequency 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 21Ā kA 50Ā % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
21Ā kA 50Ā % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7500Ā A 75Ā % conforming to EN 60898-1 – 230 V AC 50/60 Hz
7500Ā A 75Ā % conforming to IEC 60898-1 – 230 V AC 50/60 Hz
15Ā kA 50Ā % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz
15Ā kA 50Ā % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz
15Ā kA 100Ā % conforming to EN 60947-2 – 72 V DC
15Ā kA 100Ā % conforming to IEC 60947-2 – 72 V DC
20Ā kA 100Ā % conforming to EN 60947-2 – 12…60 V DC
20Ā kA 100Ā % conforming to IEC 60947-2 – 12…60 V DClimitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1[Ui] rated insulation voltage 500Ā V AC 50/60 Hz conforming to EN 60947-2
500Ā V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN 60947-2
6Ā kV conforming to IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Fixedmounting support DIN railcomb busbar and distribution block compatibility Top or bottom: YES9 mm pitches 2height 85Ā mmwidth 18Ā mmdepth 78.5Ā mmnet weight 0.215Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesconnections – terminals Single terminal (top or bottom) 1ā¦25Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦16Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 2Ā N.m top or bottomearth-leakage protection WithoutSKU: n/a
There are no reviews yet.