Schneider Electric Miniature Circuit Breaker, Easy9, 1P, 16 A, C Curve, 6000 A
Schneider Electric Miniature Circuit Breaker, Easy9, 1P, 16 A, C Curve, 6000 A
₦2,000.00
Compare-
Electro, SOCKETS, SOCKETS & SWITCHES
BG 13A Switched Double Socket with 2 x USB Charger (3.1A Output) Screwless BG Nexus
Electro, SOCKETS, SOCKETS & SWITCHESBG 13A Switched Double Socket with 2 x USB Charger (3.1A Output) Screwless BG Nexus
BG FBN22U Flat Plate Black Nickel 13A Switched Double Socket with 2 x USB Charger (3.1A Output) Screwless
The BG Electrical FBN22U Flat Plate Black Nickel 2 Gang 13A Socket Black Insert is part of the extensive BG Nexus Flat Plate range of superior wiring accessories that will add the perfect finishing touch to your décor.
Brand BG Nexus Standards BS 5733 & BS EN 60930 Dimensions 147.9mm x 87.4mm x 31mm (L,H,D) Finish Black Nickel Fixing Centres 120.6mm Installation Secure easy to fit “Clip on, Clip off” frontplate design Output Tolerance <5% Mounting Box 35mm – supplied with optional 10mm spacer for 25mm box retrofit Plate Thickness 5mm Power 13 Amp, 240V~ Socket Type Switched Stand By Power <50mW Terminal Capacity 3 x 2.5mm2Â 3 x 4mm2Â 2 x 6mm2 Terminal Screw Colour coded terminals with backed out Captive screws for easy installation USB Output 5V ……3.1A (Output shared Across Two Ports) SKU: n/a -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
Switch disconnector iSW – 2P – 100 A – 415 V A9S65291 ISOLATOR SWITCH
Schneider Circuit Breakers, SCHNEIDER SECTIONSSwitch disconnector iSW – 2P – 100 A – 415 V A9S65291 ISOLATOR SWITCH
Main range Acti 9product name Acti 9 iSWproduct or component type Switch disconnectordevice short name ISWdevice application Isolation
Controlpoles description 2Putilisation category AC-22Asuitability for isolation YesComplementary [Ie] rated operational current 100 A at 415 V AC 50/60 Hz[Ue] rated operational voltage 415 V AC 50/60 Hz[Icm] rated short-circuit making capacity 5 kA switch-disconnector alone[Icw] rated short-time withstand current 1500 A[Ui] rated insulation voltage 500 V AC 50/60 Hz[Uimp] rated impulse withstand voltage 6 kVcontrol type Togglelocal signalling ON/OFF indicationcontact position indicator Yesmounting mode Fixedmounting support DIN railcomb busbar and distribution block compatibility Top or bottom: YES9 mm pitches 4height 85 mmwidth 36 mmdepth 73 mmcolour Whitemechanical durability 20000 cycleselectrical durability 10000 cyclesconnections – terminals Tunnel type terminals (top or bottom) – <= 1 x 50 mm² – rigid
Tunnel type terminals (top or bottom) – <= 1 x 35 mm² – flexible
Tunnel type terminals (top or bottom) – <= 1 x 35 mm² – flexible with ferrulewire stripping length 9 mmtightening torque 3.5 N.mSKU: n/a -
ELECTRICAL INDUSTRIAL, Electro, RECLINE CABLES
Cometstar Nigeria Cable NAY 4 X 95.0MM
The construction and material are determined by three main factors:
• Working voltage, determining the thickness of the insulation;
• Current-carrying capacity, determining the cross-sectional size of the conductor(s);
• Environmental conditions such as temperature, water, chemical or sunlight exposure, and mechanical impact, determining the form and composition of the outer cable jacketSKU: Cometstar Nigeria Cable NAY 4 X 95.0MM -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
Acti9 iC60N 1P 4A C Miniature Circuit breaker A9F44104
Schneider Circuit Breakers, SCHNEIDER SECTIONSActi9 iC60N 1P 4A C Miniature Circuit breaker A9F44104
Main range Acti 9product name Disbo iC60product or component type Miniature circuit-breakerdevice short name IC60Npoles description 1Pnumber of protected poles 1[In] rated current 4Â Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 50Â kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
50Â kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
50Â kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Â kA Icu at 12…48 V DC conforming to EN/IEC 60947-2
6Â kA Icu at 72 V DC conforming to EN/IEC 60947-2
6000Â A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1utilisation category Category A conforming to EN/IEC 60947-2Complementary network frequency 50/60 Hz[Ue] rated operational voltage 240 V AC 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 50Â kA 100Â % conforming to EN/IEC 60947-2 – 12…60 V AC 50/60 Hz
50Â kA 100Â % conforming to EN/IEC 60947-2 – 100…133 V AC 50/60 Hz
50Â kA 100Â % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
6000Â A 100Â % conforming to EN/IEC 60898-1 – 240 V AC 50/60 Hz
15Â kA 100Â % conforming to EN/IEC 60947-2 – 12…48 V DC
6 kA 100 % conforming to EN/IEC 60947-2 – 72 V DClimitation class 3 conforming to EN/IEC 60947-2[Ui] rated insulation voltage 500 V AC 50/60 Hz[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Clip-onmounting support Rail9 mm pitches 2height 85 mmwidth 18 mmdepth 78.5 mmnet weight 0.125 kgcolour Whitemechanical durability 20000 cycleselectrical durability 10000 cyclesprovision for padlocking Padlockableconnections – terminals Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexiblewire stripping length 14 mm for top or bottom connectiontightening torque 2 N.m top or bottomearth-leakage protection Separate blockSKU: n/a -
ACCESSORIES, ELECTRICAL FITTINGS, ELECTRICAL INDUSTRIAL, Electro, SOLAR POWERED
153-5700: 12V HEAVY DUTY MAINTENANCE-FREE BATTERY Cat
ACCESSORIES, ELECTRICAL FITTINGS, ELECTRICAL INDUSTRIAL, Electro, SOLAR POWERED153-5700: 12V HEAVY DUTY MAINTENANCE-FREE BATTERY Cat
Description:
Engineered to withstand the toughest environments, this Cat maintenance-free Heavy Duty battery lasts three times longer than conventional batteries. It features a vibration resistant design, and can be quickly recharged. It provides the starting power needed for a variety of applications, especially in cold climates. Cat batteries are held to a higher standard than the competitors, with over 100 different performance tests to ensure the delivery of unmatched power.Attributes:
• 1125 cold cranking amps
• 305 reserve capacity minutes
• 145 amp hour capacity
• Size group 4D
• Forged SAE terminals
• Removeable caps
• Reinforced casing
• Flame arrestor safety veApplications:
• Construction and mining
• Electric power
• Machine
• On-highway truck and busSKU: n/a
There are no reviews yet.