Keep your cables tidy with these handy ties.
Cable Ties Black 300mm
Always read instructions
₦1,500.00
CompareBased on 0 reviews
Be the first to review “Cable Ties Black 300mm”
-
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
ABB SACE Tmax XT1B 160 Breaker 32A
A complete range of moulded case circuit-breakers up to 3200 A.
All the circuit-breakers, both three-pole and four-pole, are available in the fixed version; sizes T4 and T5 in the plug-in version and T4, T5, T6, and T7 also in the withdrawable one.
* High breaking capacity in compact dimensions
High values of short circuit breaking capacity are guaranteed at different voltage levels, without compromising overall dimensions.* Flexibility of use
Thermomagnetic and electronic trip units are available for use in AC/DC or in AC only. It is possible to interchange trip units keeping the
same breaking part, so that installation can be upgraded with fewer costs.* Advanced protection
A complete range of electronic trip units is suitable for different level of protection, even enhancing selectivity values with Early Fault
Detection and Prevention algorithm.SKU: ABB TXB3 -
DISTRIBUTION BOARDS, DISTRIBUTION BOARDS, Electro
Hager 6 Way 100A Single Phase Consumer Units DB C/W MCB
DISTRIBUTION BOARDS, DISTRIBUTION BOARDS, ElectroHager 6 Way 100A Single Phase Consumer Units DB C/W MCB
Features
These are most elegantly designed DBs, to suit the decor of homes
Raised neutral link for easy wiring
Spring loaded outer cover swings open by just pressing the lock as in case of Elegance series.
Supplied with masking sheet to protect components from cement during plastering
Supplied with neutral & earth link, top & bottom detachable platesSKU: 267 -
CIRCUIT BREAKERS
TeSys Schneider Electric Overload Relays 4-6amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.SKU: Overload1
There are no reviews yet.