The ceiling lamp
Illuminate your room with style and elegance with our ceiling lighting fitting, with the look of cut crystal, the shades give this simple ceiling light an Art Deco look.
₦18,500.00
CompareThe ceiling lamp
Weight | 2 kg |
---|
Recommended Solar Panel Wattage – 1000 Wp, 24V with OCV of 36V to 45V
AC Input – 230V AC, 50 Hz
AC output – 1500VA – 230V AC, 50 Hz
DC output – 12V, 5A
Recommended Battery Size – 24V, 100Ah to 200Ah
Recommended Battery type – Supports Tubular, Flat plate, GEL/VRLA battery
Product dimensions in mm (LxWxH) – 375 x 315 x 150
Safety and reliability – Protected against short-circuit, High temperature and Internal fault protection
Cap-Base |
E40 [ E40]
|
Operating Position |
UNIVERSAL [ Any or Universal (U)]
|
Life to 5% Failures (Nom) |
12000 h
|
Life to 20% Failures (Nom) |
20000 h
|
Life to 50% Failures (Nom) |
28000 h
|
System Description |
External Ignitor
|
Color Code |
220 [ CCT of 2000K]
|
Luminous Flux (Rated) (Min) |
43200 lm
|
Luminous Flux (Rated) (Nom) |
48000 lm
|
Lumen Maintenance 2000 h (Min) |
94 %
|
Lumen Maintenance 2000 h (Nom) |
97 %
|
Lumen Maintenance 5000 h (Min) |
88 %
|
Lumen Maintenance 5000 h (Nom) |
94 %
|
Correlated Color Temperature (Nom) |
2000 K
|
Luminous Efficacy (rated) (Nom) |
123 lm/W
|
Color Rendering Index (Max) |
25
|
Color Rendering Index (Nom) |
–
|
Power (Nom) |
392.0 W
|
Lamp Current (EM) (Nom) |
4.6 A
|
Ignition Supply Voltage (Max) |
198 V
|
Ignition Peak Voltage (Max) |
2800 V
|
Re-Ignition Time (Min) (Max) |
120 s
|
Ignition Time (Max) |
5 s
|
Voltage (Max) |
115 V
|
Voltage (Min) |
85 V
|
Voltage (Nom) |
100 V
|
Dimmable |
Yes
|
Run-Up Time 90% (Max) |
5 min
|
Bulb Finish |
Clear
|
Cap-Base Information |
–
|
Energy Efficiency Label (EEL) |
A+
|
Mercury (Hg) Content (Nom) |
24.5 mg
|
Energy Consumption kWh/1000 h |
431 kWh
|
Bulb Temperature (Max) |
450 °C
|
Cap-Base Temperature (Max) |
250 °C
|
Full product code |
871829121292800
|
Order product name |
SON-T 400W E E40 SL/12
|
EAN/UPC – Product |
8718291212928
|
Order code |
928487300098
|
Numerator – Quantity Per Pack |
1
|
Numerator – Packs per outer box |
12
|
Material Nr. (12NC) |
928487300098
|
Net Weight (Piece) |
0.181 kg
|
Control electric circuits. Protect people against indirect contacts and additional protection against direct contacts. Protect installations against fire hazard due to insulation faults. Residual current circuit breakers are used in housing, tertiary sector and industry.
Rated Power(W): 6/12/18/24W
Size: φ120*120*40mm/φ174*174*40mm/φ225*225*40mm/φ300*300*40mm
Input Voltage(V): AC85-265V
LED Type: SMD
Lumen(LM): 60-80LM/W
Frequency Range(Hz): 50-60Hz
Beam angle(Degree): 180°
Color Temperature(K): 2700K-6500K
CRI(Ra): >70
Power factor(PF): >0.55
LED Chip Brand: San’an
Material: Aluminum+Pmma
Working Temperature: -20℃~+45℃
range of product |
EasyPact
|
|
---|---|---|
product or component type |
Circuit breaker
|
|
device short name |
Easypact EZC100F
|
|
circuit breaker name |
Easypact EZC100F
|
|
device application |
Distribution
|
|
poles description |
3P
|
|
protected poles description |
3t
|
|
network type |
AC
DC |
|
network frequency |
50/60 Hz
|
|
[In] rated current |
100 A at 40 °C
|
|
[Ui] rated insulation voltage |
690 V AC 50/60 Hz conforming to IEC 60947-2
|
|
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947-2
|
|
[Ue] rated operational voltage |
550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2 |
|
breaking capacity code |
F
|
|
breaking capacity |
25 kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
|
[Ics] rated service breaking capacity |
12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
|
suitability for isolation |
Yes conforming to IEC 60947-2
|
|
utilisation category |
Category A
|
|
trip unit name |
TM-D
|
|
trip unit technology |
Thermal-magnetic
|
|
trip unit rating |
15 A at 50 °C
|
|
protection type |
Short-circuit protection
Overload protection |
|
pollution degree |
3 conforming to IEC 60664-1
3 conforming to IEC 947-1 |
control type |
Toggle
|
|
---|---|---|
mounting mode |
Fixed
|
|
mounting support |
Backplate
|
|
upside connection |
Front
|
|
downside connection |
Front
|
|
mechanical durability |
8500 cycles
|
|
electrical durability |
Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
|
|
connection pitch |
25 mm
|
|
local signalling |
Positive contact indication
|
|
neutral protection setting |
Without protection
|
|
earth-leakage protection |
Without
|
|
height |
130 mm
|
|
width |
75 mm
|
|
depth |
60 mm
|
There are no reviews yet.