CE Cerificated 86*86mm vertical mounting size ļ¼60mm
CHINT, Electro, SOCKETS, SOCKETS & SWITCHES
CHINT 13A single socket switch-
Availability:
14354 in stock (can be backordered)
- 1-gang 3-pin switched socket with indication lamp 13A 250V AC
₦4,600.00
14354 in stock (can be backordered)
CompareBased on 0 reviews
Be the first to review “CHINT 13A single socket switch-”
-
LIGHT SWITCHES & ELECTRICAL SOCKETS
1 Gang 350VA, 50Hz Full-Flat Universal Dimmer with LED, White E8431EPD4_WE
LIGHT SWITCHES & ELECTRICAL SOCKETS1 Gang 350VA, 50Hz Full-Flat Universal Dimmer with LED, White E8431EPD4_WE
Main product or component type Dimmerlocal signalling On: indicator light, LED (amber)
Off: indicator light, LED (blue)additional information With memory push[Ue] rated operational voltage 220…240 V AC 50 Hzmaterial Brass: metal parts
Polycarbonate: plastic part
Steel: metal partscover frame colour tint WhiteComplementary wiring device mounting Flush
Surfaceclamping connection capacity 2 x 4 mmĀ² for solid cable(s)
2 x 4 mmĀ² for stranded cable(s)
3 x 2.5 mmĀ² for solid cable(s)
3 x 2.5 mmĀ² for stranded cable(s)rated operational power in VA 350Ā VAnumber of gangs 1 gangload type LV halogen
Incandescent lampembedding depth 6Ā mmwidth 87Ā mmheight 87Ā mmdepth 35Ā mmSKU: n/a -
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONS
Acti9 iC60N 1P 40A C Miniature Circuit breaker A9F44140
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONSActi9 iC60N 1P 40A C Miniature Circuit breaker A9F44140
Main range Acti 9product name Disbo iC60product or component type Miniature circuit-breakerdevice short name IC60Npoles description 1Pnumber of protected poles 1[In] rated current 40Ā Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 15Ā kA Icu at 12…48 V DC conforming to EN/IEC 60947-2
6Ā kA Icu at 72 V DC conforming to EN/IEC 60947-2
6000Ā A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1
36Ā kA Icu at 10…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
20Ā kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
10Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2utilisation category Category A conforming to EN/IEC 60947-2Complementary network frequency 50/60 Hz[Ue] rated operational voltage 240 V AC 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 27Ā kA 75Ā % conforming to EN/IEC 60947-2 – 10…60 V AC 50/60 Hz
15Ā kA 75Ā % conforming to EN/IEC 60947-2 – 100…133 V AC 50/60 Hz
7.5Ā kA 75Ā % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
6000Ā A 100Ā % conforming to EN/IEC 60898-1 – 240 V AC 50/60 Hz
15Ā kA 100Ā % conforming to EN/IEC 60947-2 – 12…48 V DC
6Ā kA 100Ā % conforming to EN/IEC 60947-2 – 72 V DClimitation class 3 conforming to EN/IEC 60947-2[Ui] rated insulation voltage 500Ā V AC 50/60 Hz[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN/IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Clip-onmounting support Rail9 mm pitches 2height 85Ā mmwidth 18Ā mmdepth 78.5Ā mmnet weight 0.125Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesprovision for padlocking Padlockableconnections – terminals Single terminal (top or bottom) 1ā¦35Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦25Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 3.5Ā N.m top or bottomearth-leakage protection Separate blockSKU: n/a -
-
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONS
Easy9 Residual Current Circuit Breaker – 2P – 25 A – 30 mA – AC type – 230 V EZ9R34225
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONSEasy9 Residual Current Circuit Breaker – 2P – 25 A – 30 mA – AC type – 230 V EZ9R34225
Main range of product Easy9product or component type Residual current circuit breaker (RCCB)device short name Easy9 RCCBPoles 2Pneutral position Left[In] rated current 25Ā Anetwork type ACearth-leakage sensitivity 30Ā mAearth-leakage protection time delay Instantaneousearth-leakage protection class Type ACrated breaking and making capacity 500Ā Arated conditional short-circuit current Easy9 MCB: 4500Ā A 25Ā AComplementary device location in system Outgoernetwork frequency 50 Hz[Ue] rated operational voltage 230 V AC 50 Hzresidual current tripping technology Voltage dependent[Ui] rated insulation voltage 440Ā V AC[Uimp] rated impulse withstand voltage 4Ā kVsurge current 250Ā Acontact position indicator Yescontrol type Togglemounting mode Clip-onmounting support DIN railcomb busbar and distribution block compatibility Top: YES9 mm pitches 4height 82Ā mmwidth 36Ā mmdepth 72Ā mmcolour Grey (RAL 7035)mechanical durability 5000Ā cycleselectrical durability AC: 2000Ā cycles 230 V AC 50 Hzconnections – terminals Tunnel type terminal (top or bottom) 1ā¦25Ā mmĀ² rigid
Tunnel type terminal (top or bottom) 1ā¦16Ā mmĀ² flexibletightening torque 2.5Ā N.m top or bottommarket segment Residential
Small commercialSKU: n/a
There are no reviews yet.