Schneider Circuit Breakers, SCHNEIDER SECTIONS
Acti9 iC60N 4P 3A C Miniature Circuit breaker A9F44403
Schneider Circuit Breakers, SCHNEIDER SECTIONSActi9 iC60N 4P 3A C Miniature Circuit breaker A9F44403
Main range Acti 9product name Disbo iC60product or component type Miniature circuit-breakerdevice short name IC60Npoles description 4Pnumber of protected poles 4[In] rated current 3Ā Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 50Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
50Ā kA Icu at 12…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
50Ā kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
25Ā kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
6Ā kA Icu at 100…133 V DC conforming to EN/IEC 60947-2
6000Ā A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1utilisation category Category A conforming to EN/IEC 60947-2Complementary network frequency 50/60 Hz[Ue] rated operational voltage 440 V AC 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 50Ā kA 100Ā % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
50Ā kA 100Ā % conforming to EN/IEC 60947-2 – 12…133 V AC 50/60 Hz
50Ā kA 100Ā % conforming to EN/IEC 60947-2 – 380…415 V AC 50/60 Hz
25Ā kA 100Ā % conforming to EN/IEC 60947-2 – 440 V AC 50/60 Hz
6000Ā A 100Ā % conforming to EN/IEC 60898-1 – 415 V AC 50/60 Hz
6Ā kA 100Ā % conforming to EN/IEC 60947-2 – 100…133 V DClimitation class 3 conforming to EN/IEC 60947-2[Ui] rated insulation voltage 500Ā V AC 50/60 Hz[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN/IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Clip-onmounting support Rail9 mm pitches 8height 85Ā mmwidth 72Ā mmdepth 78.5Ā mmnet weight 0.5Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesprovision for padlocking Padlockableconnections – terminals Single terminal (top or bottom) 1ā¦25Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦16Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 2Ā N.m top or bottomearth-leakage protection Separate blockSKU: n/a -
ELECTRICAL FITTINGS, Electro, HOME&OFFICE LIGHTING, LED LIGHTS, LIGHTING, OUTDOOR FITTINGS, OUTDOOR LIGHTS
PHILIPS STREETLIGHT BRP392 LED195 NW 150W 220-240V DM GM RoadFlair
ELECTRICAL FITTINGS, Electro, HOME&OFFICE LIGHTING, LED LIGHTS, LIGHTING, OUTDOOR FITTINGS, OUTDOOR LIGHTSPHILIPS STREETLIGHT BRP392 LED195 NW 150W 220-240V DM GM RoadFlair
Light Technical
- Luminous FluxĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 21,246 lm
- Standard tilt angle posttopĀ Ā Ā Ā –
- Standard tilt angle side entryĀ Ā Ā –
- Correlated Color Temperature (Nom)Ā Ā 4000 K
- Luminous Efficacy (rated) (Nom)Ā Ā Ā Ā Ā 140 lm/W
- Color rendering index (CRI)Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā >70
- Light source colorĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā 740 neutral white
- Optical cover typeĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Polycarbonate micro lens optic
Operating and Electrical
- Input VoltageĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā –Ā Ā 220 to 240 V
- Line FrequencyĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā –Ā 50 or 60 Hz
- Power ConsumptionĀ Ā Ā Ā Ā Ā Ā Ā –Ā 150 W
- Power Factor (Fraction)Ā Ā Ā Ā Ā – 0.9
- ConnectionĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā –Ā Mains outlet socket
- CableĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā –
Mechanical and Housing
- Housing MaterialĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā –Ā Ā Aluminum die cast
- Optical cover materialĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā –Ā Ā Polycarbonate
- Housing ColorĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā –Ā Gray
- Mounting deviceĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā – Side-entry for diameter 48 to 60 mm
- Optical cover shapeĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā – Ball, globular
- Optical cover finishĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā – Frosted
- Overall lengthĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā – 492 mm
- Overall widthĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā – 295 mm
- Overall heightĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā – 86 mm
- Effective projected areaĀ Ā Ā Ā Ā Ā Ā Ā Ā – 0.14 mĀ²
- Dimensions (Height x Width x Depth)Ā – 86 x 295 x 492 mm
SKU: n/a -
LIGHT SWITCHES & ELECTRICAL SOCKETS, SCHNEIDER SECTIONS
Ultimate Screwless flat plate – rocker plate switch – 3 gangs – black nickel GU1432BBN
LIGHT SWITCHES & ELECTRICAL SOCKETS, SCHNEIDER SECTIONSUltimate Screwless flat plate – rocker plate switch – 3 gangs – black nickel GU1432BBN
Main range of product Ultimaterange Ultimateaesthetic name Screwless flat plateproduct or component type Plate switchcontrol type Rockerswitch function 1-pole 2-wayrated current 16 AX at 230 V ACComplementary connections – terminals Screw terminalsmaterial Steelquantity per set Set of 1number of gangs 3 gangsdevice mounting Wall mountedheight 88Ā mmwidth 88Ā mmdepth 24Ā mmSKU: n/a -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
IC60H – miniature circuit breaker – 1P – 50A – C curve A9F84150
Schneider Circuit Breakers, SCHNEIDER SECTIONSIC60H – miniature circuit breaker – 1P – 50A – C curve A9F84150
Main device application Distributionrange Acti 9product name Acti 9 iC60product or component type Miniature circuit-breakerdevice short name IC60Hpoles description 1Pnumber of protected poles 1[In] rated current 50Ā Anetwork type DC
ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000Ā A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
15Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
42Ā kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
30Ā kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Ā kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
20Ā kA Icu at 12…60 V DC conforming to EN/IEC 60947-2utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2standards IEC 60898-1
EN 60898-1
IEC 60947-2
EN 60947-2Complementary network frequency 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 21Ā kA 50Ā % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
21Ā kA 50Ā % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7500Ā A 75Ā % conforming to EN 60898-1 – 230 V AC 50/60 Hz
7500Ā A 75Ā % conforming to IEC 60898-1 – 230 V AC 50/60 Hz
15Ā kA 50Ā % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz
15Ā kA 50Ā % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz
15Ā kA 100Ā % conforming to EN 60947-2 – 72 V DC
15Ā kA 100Ā % conforming to IEC 60947-2 – 72 V DC
20Ā kA 100Ā % conforming to EN 60947-2 – 12…60 V DC
20Ā kA 100Ā % conforming to IEC 60947-2 – 12…60 V DC[Ui] rated insulation voltage 500Ā V AC 50/60 Hz conforming to EN 60947-2
500Ā V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN 60947-2
6Ā kV conforming to IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Fixedmounting support DIN railcomb busbar and distribution block compatibility Top or bottom: YES9 mm pitches 2height 85Ā mmwidth 18Ā mmdepth 78.5Ā mmnet weight 0.215Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesconnections – terminals Single terminal (top or bottom) 1ā¦35Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦25Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 3.5Ā N.m top or bottomearth-leakage protection WithoutSKU: n/a -
ELECTRICAL INDUSTRIAL, TRANSFORMER
MEKSAN Transformer 750kVA 11/415kV
Meksan Transformer manufactureĀ distribution and power transformer from 50 kVA up to 50 MVA.Ā Ā Our products are produced in accordance with theĀ TS 267Ā and theĀ IEC60076Ā Ā standards. Our production is documented with theĀ TSEĀ (TĆ¼rkish Standard Institue) standards confortmity,Ā ISO 9001:2000Ā quality system andĀ ISO 14001Ā environmental management system certificates.
SKU: n/a
There are no reviews yet.