Schneider Circuit Breakers, SCHNEIDER SECTIONS
Acti9 iC60N 4P 3A C Miniature Circuit breaker A9F44403
Schneider Circuit Breakers, SCHNEIDER SECTIONSActi9 iC60N 4P 3A C Miniature Circuit breaker A9F44403
Main range Acti 9product name Disbo iC60product or component type Miniature circuit-breakerdevice short name IC60Npoles description 4Pnumber of protected poles 4[In] rated current 3Ā Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 50Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
50Ā kA Icu at 12…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
50Ā kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
25Ā kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
6Ā kA Icu at 100…133 V DC conforming to EN/IEC 60947-2
6000Ā A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1utilisation category Category A conforming to EN/IEC 60947-2Complementary network frequency 50/60 Hz[Ue] rated operational voltage 440 V AC 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 50Ā kA 100Ā % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
50Ā kA 100Ā % conforming to EN/IEC 60947-2 – 12…133 V AC 50/60 Hz
50Ā kA 100Ā % conforming to EN/IEC 60947-2 – 380…415 V AC 50/60 Hz
25Ā kA 100Ā % conforming to EN/IEC 60947-2 – 440 V AC 50/60 Hz
6000Ā A 100Ā % conforming to EN/IEC 60898-1 – 415 V AC 50/60 Hz
6Ā kA 100Ā % conforming to EN/IEC 60947-2 – 100…133 V DClimitation class 3 conforming to EN/IEC 60947-2[Ui] rated insulation voltage 500Ā V AC 50/60 Hz[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN/IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Clip-onmounting support Rail9 mm pitches 8height 85Ā mmwidth 72Ā mmdepth 78.5Ā mmnet weight 0.5Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesprovision for padlocking Padlockableconnections – terminals Single terminal (top or bottom) 1ā¦25Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦16Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 2Ā N.m top or bottomearth-leakage protection Separate blockSKU: n/a -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
Miniature circuit-breaker, Acti9 iC60H, 2P, 16 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2) A9F84216
Schneider Circuit Breakers, SCHNEIDER SECTIONSMiniature circuit-breaker, Acti9 iC60H, 2P, 16 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2) A9F84216
Main device application Distributionrange Acti 9product name Acti 9 iC60product or component type Miniature circuit-breakerdevice short name IC60Hpoles description 2Pnumber of protected poles 2[In] rated current 16Ā Anetwork type DC
ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000Ā A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
42Ā kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
10Ā kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Ā kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
30Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Ā kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
42Ā kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2standards EN 60898-1
IEC 60898-1
EN 60947-2
IEC 60947-2Complementary network frequency 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 15Ā kA 50Ā % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz
5Ā kA 50Ā % conforming to EN 60947-2 – 440 V AC 50/60 Hz
15Ā kA 50Ā % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz
5Ā kA 50Ā % conforming to IEC 60947-2 – 440 V AC 50/60 Hz
7500Ā A 75Ā % conforming to EN 60898-1 – 400 V AC 50/60 Hz
7500Ā A 75Ā % conforming to IEC 60898-1 – 400 V AC 50/60 Hz
21Ā kA 50Ā % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz
21Ā kA 50Ā % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz
15Ā kA 100Ā % conforming to IEC 60947-2 – 72…125 V DC
15Ā kA 100Ā % conforming to EN 60947-2 – 72…125 V DClimitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1[Ui] rated insulation voltage 500Ā V AC 50/60 Hz conforming to EN 60947-2
500Ā V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN 60947-2
6Ā kV conforming to IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Fixedmounting support DIN railcomb busbar and distribution block compatibility Top or bottom: YES9 mm pitches 4height 85Ā mmwidth 36Ā mmdepth 78.5Ā mmnet weight 0.25Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesconnections – terminals Single terminal (top or bottom) 1ā¦25Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦16Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 2Ā N.m top or bottomearth-leakage protection Separate blockSKU: n/a -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
IC60H – miniature circuit breaker – 1P – 40A – C curve A9F84140
Schneider Circuit Breakers, SCHNEIDER SECTIONSIC60H – miniature circuit breaker – 1P – 40A – C curve A9F84140
Main device application Distributionrange Acti 9product name Acti 9 iC60product or component type Miniature circuit-breakerdevice short name IC60Hpoles description 1Pnumber of protected poles 1[In] rated current 40Ā Anetwork type AC
DCtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000Ā A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
15Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
42Ā kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
30Ā kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Ā kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
20Ā kA Icu at 12…60 V DC conforming to EN/IEC 60947-2utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2standards IEC 60947-2
IEC 60898-1
EN 60898-1
EN 60947-2Complementary network frequency 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 21Ā kA 50Ā % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
21Ā kA 50Ā % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7500Ā A 75Ā % conforming to EN 60898-1 – 230 V AC 50/60 Hz
7500Ā A 75Ā % conforming to IEC 60898-1 – 230 V AC 50/60 Hz
15Ā kA 50Ā % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz
15Ā kA 50Ā % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz
15Ā kA 100Ā % conforming to EN 60947-2 – 72 V DC
15Ā kA 100Ā % conforming to IEC 60947-2 – 72 V DC
20Ā kA 100Ā % conforming to EN 60947-2 – 12…60 V DC
20Ā kA 100Ā % conforming to IEC 60947-2 – 12…60 V DClimitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1[Ui] rated insulation voltage 500Ā V AC 50/60 Hz conforming to EN 60947-2
500Ā V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN 60947-2
6Ā kV conforming to IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Fixedmounting support DIN railcomb busbar and distribution block compatibility Top or bottom: YES9 mm pitches 2height 85Ā mmwidth 18Ā mmdepth 78.5Ā mmnet weight 0.215Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesconnections – terminals Single terminal (top or bottom) 1ā¦35Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦25Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 3.5Ā N.m top or bottomearth-leakage protection WithoutSKU: n/a
There are no reviews yet.