Lisse – Plate Switch – 3 gang 2 way – 10AX Mocha Bronze with Black Interior GGBL1032BMB
range |
Lisse
|
|
---|---|---|
aesthetic name |
Screwless deco
|
|
product or component type |
Plate switch
|
|
device presentation |
Complete product
|
|
quantity per set |
Set of 10
|
switch function |
2-way
|
|
---|---|---|
control type |
Rocker
|
|
number of gangs |
3 gangs
|
|
device mounting |
Wall mounted
|
|
fixing mode |
Concealed screws
|
|
connections – terminals |
Screw terminals
|
|
material |
Stainless steel
|
|
surface finish |
Matt
|
|
type of packing |
Box
|
|
height |
87 mm
|
|
width |
87 mm
|
|
depth |
25 mm
|
|
net weight |
0.136 kg
|
₦8,500.00
Compare-
SOLAR POWERED
Ritar 200AH Deep 12V AGM Deep Cycle Battery
Ritar Power Valve Regulated Lead Acid (VRLA) battery is a premium quality battery with wide application is critical power installations and offers long design life in float service. Ritar Power prides its RA series batteries as being designed with up-dated AGM valve regulated technology and made of high purity raw materials for high consistency and better performance battery.
Long design life
Low self-discharge rate
Good high rate discharge performance
Wide operation temperature range
Application: telecom systems, fire & alarm systems, emergency systems, power tools, medical equipment, UPS/EPS, solar inverters/controllers, etc.SKU: n/a -
ELECTRICAL INDUSTRIAL, Electro, TRANSFORMER, Uncategorized
ABB 1000KVA 11/400KV Distribution Transformer
ELECTRICAL INDUSTRIAL, Electro, TRANSFORMER, UncategorizedABB 1000KVA 11/400KV Distribution Transformer
Distribution transformers are typically oil-immersed and suitable for pole-, pad- or ground-mounting. They represent an economical option for certain networks, particularly those with low population densities.
Depending upon requirements, transformers may be connected between two phases of a three-phase system (two high voltage bushings) or from one phase to ground (single high voltage bushing).
The units are suitable for residential overhead distribution loads, as well as light commercial or industrial loads and diversified power applications.
Product scope
- Primary voltage: up to 36 kV
- Typical fluid: mineral oil
SKU: n/a -
ELECTRICAL INDUSTRIAL, Electro, RECLINE CABLES
Cometstar Nigeria Cable NAY 4 X 16.0MM
The construction and material are determined by three main factors:
• Working voltage, determining the thickness of the insulation;
• Current-carrying capacity, determining the cross-sectional size of the conductor(s);
• Environmental conditions such as temperature, water, chemical or sunlight exposure, and mechanical impact, determining the form and composition of the outer cable jacketSKU: Cometstar Nigeria Cable NAY 4 X 16.0MM -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
Miniature circuit-breaker, Acti9 iC60H, 2P, 50 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2) A9F84250
Schneider Circuit Breakers, SCHNEIDER SECTIONSMiniature circuit-breaker, Acti9 iC60H, 2P, 50 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2) A9F84250
Main device application Distributionrange Acti 9product name Acti 9 iC60product or component type Miniature circuit-breakerdevice short name IC60Hpoles description 2Pnumber of protected poles 2[In] rated current 50 Anetwork type AC
DCtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
42 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
15 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
30 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
15 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
42 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2standards IEC 60947-2
EN 60947-2
EN 60898-1
IEC 60898-1Complementary network frequency 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 15 kA 50 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
7.5 kA 50 % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz
5 kA 50 % conforming to EN 60947-2 – 440 V AC 50/60 Hz
15 kA 50 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7.5 kA 50 % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz
5 kA 50 % conforming to IEC 60947-2 – 440 V AC 50/60 Hz
7500 A 75 % conforming to EN 60898-1 – 400 V AC 50/60 Hz
7500 A 75 % conforming to IEC 60898-1 – 400 V AC 50/60 Hz
21 kA 50 % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz
21 kA 50 % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz
15 kA 100 % conforming to IEC 60947-2 – 72…125 V DC
15 kA 100 % conforming to EN 60947-2 – 72…125 V DC[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Fixedmounting support DIN railcomb busbar and distribution block compatibility Top or bottom: YES9 mm pitches 4height 85 mmwidth 36 mmdepth 78.5 mmnet weight 0.25 kgcolour Whitemechanical durability 20000 cycleselectrical durability 10000 cyclesconnections – terminals Single terminal (top or bottom) 1…35 mm² rigid
Single terminal (top or bottom) 1…25 mm² flexiblewire stripping length 14 mm for top or bottom connectiontightening torque 3.5 N.m top or bottomearth-leakage protection Separate blockSKU: n/a -
ACCESSORIES, ACCESSORIES, DISTRIBUTION BOARDS, DISTRIBUTION BOARDS, ELECTRICAL FITTINGS, ELECTRICAL INDUSTRIAL, Electro
Metal Enclosure (Empty Panel) ABB
ACCESSORIES, ACCESSORIES, DISTRIBUTION BOARDS, DISTRIBUTION BOARDS, ELECTRICAL FITTINGS, ELECTRICAL INDUSTRIAL, ElectroMetal Enclosure (Empty Panel) ABB
ZINC PLAT.PLATE 600X600MM(HXW)
Long Description:
Blind back plate for enclosure 600x600mm (HxW)
Categories
- Products » Low Voltage Products and Systems » Enclosures » General Purpose Enclosures
Ordering
-
- EAN:
- 8015646008459
-
- Minimum Order Quantity:
- 1 piece
-
- Customs Tariff Number:
- 85381000
Dimensions
-
- Product Net Width:
- 600 mm
-
- Product Net Height:
- 600 mm
-
- Product Net Depth / Length:
- 600 mm
-
- Product Net Weight:
- 5 kg
Container Information
-
- Package Level 1 Units:
- 1 piece
-
- Package Level 1 Width:
- 0.600 m
-
- Package Level 1 Height:
- 0.040 m
-
- Package Level 1 Depth / Length:
- 0.600 m
-
- Package Level 1 Gross Weight:
- 5.100 kg
-
- Package Level 1 EAN:
- 8015646008459
Additional Information
-
- Accessory Type:
- Blind internal mounting plate
-
- Material:
- Steel
-
- Order Multiple:
- 1 piece
-
- Product Main Type:
- SR2 Accessories
-
- Product Name:
- Control and Automation Board
-
- Suitable For:
- SR2 Enclosures
-
- Suitable for Product Class:
- SR2
SRX
SR2 EMC
-
- Surface Finishing:
- Galvanized
SKU: n/a -
Electro, SOCKETS & SWITCHES, SURGE PROTECTOR
Himel Single Phase Voltage Stabilizers 5kVA
Voltage stabilizer, HAVRL, relay type, 5 kVA, British type plug, 110/220 V output, 85..250 V input, with time delay
Main
Range of product – HAVRLProduct or component type – Voltage stabilizerTechnology type – RelayOutlet standard – BritishProvided equipment – User manualComplementary
Rated power in VA – 5 kVAMinimum insulating resistance – 5 MOhmMaximum [In] rated current – 22.7 AEfficiency – 90 %Input voltage limits – 85…250 VOptional feature – Bypass
Cooling fan – Input undervoltage protectionProtection type – Overvoltage
Overcurrent – Temperature rise protection
Time delay – Display typeLED – Output voltage220 V AC +/- 8 % – 110 V AC +/- 10 %Network frequency – 50/60 HzEnvironment
Ambient air temperature for operation -5…40 °CRelative humidity 0…90 %Humidity storage 0…90 %Operating altitude 0…2000 mStorage altitude 0…2000 mStandards EN 61000-6-2
EN 61000-6-4 EN 61558-1Packing Units
Unit Type of Package 1 PCENumber of Units in Package 1 1SKU: n/a
There are no reviews yet.