MEKSAN Transformer 100kVA 33/415kV
Meksan Transformer manufacture distribution and power transformer from 50 kVA up to 50 MVA.  Our products are produced in accordance with the TS 267 and the IEC60076  standards. Our production is documented with the TSE (Türkish Standard Institue) standards confortmity, ISO 9001:2000 quality system and ISO 14001 environmental management system certificates.
₦6,900,000.00
Compare-
Electro, SOCKETS, SOCKETS & SWITCHES
BG Electrical 2.1 A USB Charger and Wi-Fi Range Extender Plug Socket 822UWR
Electro, SOCKETS, SOCKETS & SWITCHESBG Electrical 2.1 A USB Charger and Wi-Fi Range Extender Plug Socket 822UWR
- Improved Wi-Fi coverage throughout your home
- Works with all wireless broadband routers
- Easy to install and setup with one-touch WPS (Wi-Fi Protected Setup)
- Perfect for streaming music and videos or playing online games
- Suitable for computers, tablets, mobile phones, games consoles, TVs
- No plug-in adapters – keep your sockets free for use
- Wireless 2.4GHz single band
- Retrofits a standard 25mm wall box
- N300 – 300Mbps speed 802.11b/g/n wireless
- Terminal capacity; 3 x 2.5mm², 3 x 4.0mm² or 2 x 6mm²
- Twin earth fitted as standard to allow a double earth facility for installations requiring high integrity protective connection Ref. BS 7671:2008
- Manufactured to BS 1363-2
- Supplied with 2 x 32mm screws and screw covers
- 86mm x 146mm x 10mm (front plate) (H x W x D)
SKU: g13 -
Electro, LED LIGHTS, LIGHTING, OUTDOOR LIGHTS, SOLAR POWERED
All In One Solar Street Light System LED Lamp 60w FL-A3-60W 9600lm
Electro, LED LIGHTS, LIGHTING, OUTDOOR LIGHTS, SOLAR POWEREDAll In One Solar Street Light System LED Lamp 60w FL-A3-60W 9600lm
Feature
1. Integrated design and source, high capacity LiFePO4 lithium battery, high energy, and long life,
light weights, green and environmental protection, do not produce any harmful substances.
2. Philips LED chip with high light efficiency which can reach 180LM/W,and whole lamp light
efficiency can reach 160LM/W at least
3. All series use MPPT controller which can increase 15%-30% charge efficiency
4. Design with high efficiency solar cell (>22%)
5. Convenient installation and maintenance, no need of cable installation or special light pole,
functional components modular design, installation and maintenance, convenient andquick replacement.
Data Sheet
Model FL-A3-60W Solar Panel 105w High capacity lithium battery 532wh Luminous flux(All light pattern) 9600lm Mounting Height 5-6M Solar panel charge  time(with strong sunlight) 8 hours by bright sunlight Rainy days support 3-5days with full charging Working time(per day) ≥12hours Color Temperature 3000-7000k(optional Light Pole diameter 70-114MM Storage temperature 0-55℃ Operating Humidity 90RH%≤ Waterproof level IP65 Package Dimensions 1315*535*145mm SKU: n/a -
Electro, SOCKETS, SOCKETS & SWITCHES
BG BRASS GEORGIAN SHAVER SOCKET OUTLET DUAL VOLTAGE BLACK INSERT
Electro, SOCKETS, SOCKETS & SWITCHESBG BRASS GEORGIAN SHAVER SOCKET OUTLET DUAL VOLTAGE BLACK INSERT
BG NBG20B Brass Georgian Shaver Socket Outlet Dual Voltage Black InsertAT A GLANCE…- Top quality Brass finish – lightly lacquered to prevent finger marks
- Black plastic insert
- Specification: 115/230V dual voltage
- Supplied with colour coded fixing screws
SKU: Volex socket2 -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
Acti9 iC60N 3P 32A C Miniature Circuit breaker A9F44332
Schneider Circuit Breakers, SCHNEIDER SECTIONSActi9 iC60N 3P 32A C Miniature Circuit breaker A9F44332
Main range Acti 9product name Disbo iC60product or component type Miniature circuit-breakerdevice short name IC60Npoles description 3Pnumber of protected poles 3[In] rated current 32Â Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 6000Â A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
36Â kA Icu at 12…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
20Â kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
10Â kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
6Â kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Â kA Icu at 100…133 V DC conforming to EN/IEC 60947-2utilisation category Category A conforming to EN/IEC 60947-2Complementary network frequency 50/60 Hz[Ue] rated operational voltage 440 V AC 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 27Â kA 75Â % conforming to EN/IEC 60947-2 – 12…133 V AC 50/60 Hz
15Â kA 75Â % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
7.5Â kA 75Â % conforming to EN/IEC 60947-2 – 380…415 V AC 50/60 Hz
4.5Â kA 75Â % conforming to EN/IEC 60947-2 – 440 V AC 50/60 Hz
6000Â A 100Â % conforming to EN/IEC 60898-1 – 415 V AC 50/60 Hz
15 kA 100 % conforming to EN/IEC 60947-2 – 100…133 V DClimitation class 3 conforming to EN/IEC 60947-2[Ui] rated insulation voltage 500 V AC 50/60 Hz[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Clip-onmounting support Rail9 mm pitches 6height 85 mmwidth 54 mmdepth 78.5 mmnet weight 0.375 kgcolour Whitemechanical durability 20000 cycleselectrical durability 10000 cyclesprovision for padlocking Padlockableconnections – terminals Single terminal (top or bottom) 1…35 mm² rigid
Single terminal (top or bottom) 1…25 mm² flexiblewire stripping length 14 mm for top or bottom connectiontightening torque 3.5 N.m top or bottomearth-leakage protection Separate blockEnvironment standards EN/IEC 60947-2
EN/IEC 60898-1IP degree of protection IP20 conforming to IEC 60529pollution degree 3 conforming to EN/IEC 60947-2tropicalisation 2 conforming to IEC 60068-1relative humidity 95 % at 55 °Cambient air temperature for operation -35…70 °Cambient air temperature for storage -40…85 °CSKU: n/a -
ACCESSORIES, ELECTRICAL INDUSTRIAL, Electro, RECLINE CABLES
Cometstar Nigeria Cable NAY 4 X 50.0MM
The construction and material are determined by three main factors:
• Working voltage, determining the thickness of the insulation;
• Current-carrying capacity, determining the cross-sectional size of the conductor(s);
• Environmental conditions such as temperature, water, chemical or sunlight exposure, and mechanical impact, determining the form and composition of the outer cable jacketSKU: Cometstar Nigeria Cable NAY 4 X 50.0MM
There are no reviews yet.