Two gang dimmer switch in satin steel the ultimate in contemporary switches. This product must be installed in accordance with local Building Regulations. If in any doubt, or where required by the law, consult a competent person who is registered with an electrical self certification scheme. Further information is available online or from your Local Authority. .
Twin 400W Dimmer Steel
Always read instructions
₦6,000.00
CompareBased on 0 reviews
Be the first to review “Twin 400W Dimmer Steel”
-
ELECTRICAL FITTINGS, Electro, FLUORESCENT FITTINGS, FLUORESENT TUBES, INDOOR LIGHTS, LIGHT BULBS, LIGHTING
Warom Explosion Proof Corrosion Proof Fluorescent Lamp 4ft Double (LED type)
ELECTRICAL FITTINGS, Electro, FLUORESCENT FITTINGS, FLUORESENT TUBES, INDOOR LIGHTS, LIGHT BULBS, LIGHTINGWarom Explosion Proof Corrosion Proof Fluorescent Lamp 4ft Double (LED type)
Widely used for the illumination of various marine platforms, chemical tankers, LNG ships and hazardous cargo wharf etc.
Can reliably work in severe environment exposed to moisture, vibration or corrosion;
Explosive hazardous atmosphere Zone 1, Zone 2, Zone 21 and Zone 22
Explosion -proof electronic ballast, wide voltage input
SKU: Explosion Proof Corrosion Proof-1 -
DISTRIBUTION BOARDS, DISTRIBUTION BOARDS, Electro
Havells 4 Way 100A Three Phase(TPN) Distribution Board C/W MCB
DISTRIBUTION BOARDS, DISTRIBUTION BOARDS, ElectroHavells 4 Way 100A Three Phase(TPN) Distribution Board C/W MCB
Features Compact DBs which occupy minimum space Raised neutral link for easy wiring Suitable for surface & fush mounting Detachable din bar with end stoppers for easy assembly of breakers Supplied with fully shielded bus-bars Level marks for providing indication for fitment in wall Supplied with neutral & earth link, top & bottom detachable plates Supplied with masking sheet to protect components from cement during plastering
SKU: 274 -
CIRCUIT BREAKERS
TeSys Schneider Electric Overload Relays 7 – 10amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.SKU: Overload4
There are no reviews yet.