CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
ABB Contactor A26-30-10 24V 50Hz / 24V 60Hz
A26 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting.
SKU: ABB1 -
DISTRIBUTION BOARDS, DISTRIBUTION BOARDS, Electro
Schneider Electric 3 Phase 12 Ways Distribution Board
DISTRIBUTION BOARDS, DISTRIBUTION BOARDS, ElectroSchneider Electric 3 Phase 12 Ways Distribution Board
Disbo-Extra Isobar is a complete range of single and 3 phase distribution boards for commercial and industrial applications.
Standard distribution boards up to 24 ways
Meter ready distribution boards up to 24 ways
Split metered distribution boards up to 22 ways
Any outgoing way can be converted to switch the Neutral
Fully type tested conditional short circuit rating of 25kA to BS EN 61439-3
High performance MCB 10kA BS EN 60898 15kA BS EN 60947-2 in B, C or D curve 1, 2, 3, 4 pole
250A Busbar rating
Isobar disconnection to BS EN 60947-3 ensuring unused outgoing ways are isolated
Option of switching outgoing neutral on all boards using distributed neutral kit
Terminal block for feeding up to 100A
Range of incomers: switch disconnectors, residual current devices, terminal blocks, MCCB
Single pole RCBO for new or retrofit maintaining device density
Full range of device accessories and auxiliaries
Knockouts for cable gland and conduit mixed to suit the installation needs without loss of space
Removable insulated pan assembly
Fully shrouded neutral
Split neutral bars
Removable gland plates
Optional metering, dual supply, surge protection and contactor on incoming Metered extension enclosures.SKU: Schneider9 -
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
ABB Contactor A16-30-10 600V 50Hz
A16 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A… series 1-stack 3-pole contactors are of the block type design.
SKU: ABB2 -
-
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
ABB Contactor – A12-30-10 220V 50Hz/190V 60Hz-
A12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A… series 1-stack 3-pole contactors are of the block type design.
SKU: ABB3 -
DISTRIBUTION BOARDS, DISTRIBUTION BOARDS, Electro
Schneider Electric 1 Phase 8 Ways DIN ROW Distribution Board enclosure
DISTRIBUTION BOARDS, DISTRIBUTION BOARDS, ElectroSchneider Electric 1 Phase 8 Ways DIN ROW Distribution Board enclosure
Features
* Device Mounting – Flush
* Product or Component Type – Distribution Board
* Product Range – Disbo
* Number of Phases – 1 Phase
* Type of Inomer – 2P Isolator 63A
* Number of Ways – 8 WayBenefits:
– Spectacular Design – Blends seamlessly with interiors
– Maximized Wiring Space – Convenient and Safe wiring
– Adaptable – Total Flexibility for ease of installation and usage
– Robust Architecture – Perfect blend of Strength & WeightTechnically Proven – Safety Guaranteed
– Technically Proven – Safety GuaranteedApplications:
It is housing to mount multiple electrical Modular devices (like MCBs, RCCBs, Surge Protection Devices, Change over switch, Isolators, indicating devices etc.) used for distribution, protection , control and automation at final distribution level.SKU: Schneider11 -
-
DISTRIBUTION BOARDS, DISTRIBUTION BOARDS, Electro
Schneider Electric 1 Phase 10 Ways DIN ROW Distribution Board enclosure
DISTRIBUTION BOARDS, DISTRIBUTION BOARDS, ElectroSchneider Electric 1 Phase 10 Ways DIN ROW Distribution Board enclosure
Features
* Device Mounting – Flush
* Product or Component Type – Distribution Board
* Product Range – Disbo
* Number of Phases – 1 Phase
* Type of Inomer – 2P Isolator 63A
* Number of Ways – 10 WayBenefits:
– Spectacular Design – Blends seamlessly with interiors
– Maximized Wiring Space – Convenient and Safe wiring
– Adaptable – Total Flexibility for ease of installation and usage
– Robust Architecture – Perfect blend of Strength & WeightTechnically Proven – Safety Guaranteed
– Technically Proven – Safety GuaranteedApplications:
It is housing to mount multiple electrical Modular devices (like MCBs, RCCBs, Surge Protection Devices, Change over switch, Isolators, indicating devices etc.) used for distribution, protection , control and automation at final distribution level.SKU: Schneider12 -
-
CIRCUIT BREAKERS
TeSys Schneider Electric Overload Relays 4-6amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.SKU: Overload1 -
CIRCUIT BREAKERS
TeSys Schneider Electric Overload Relays 2.3-4amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.SKU: Overload2 -
CIRCUIT BREAKERS
TeSys Schneider Electric Overload Relays 1.6 – 2.5amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.SKU: Overload3