Electro, SOCKETS, SOCKETS & SWITCHES, SURGE PROTECTOR
BG SOCKET 13AMP 2-GANG SWITCHED SOCKET RCD – LUCECO
- Maximum load 3120 watts 240V AC
- 30 mA trip speed 40 ms
- Latching type
- Terminal capacity 3 x 2.5mm², 2 x 4.0mm² & 1 x 6.0mm²
- Manufactured to BS 7288:1990
- 10mm Spacer provided for shallow boxes
- Minimum mounting box depth 35mm
₦37,500.00
Compare-
ELECTRICAL FITTINGS, Electro, INDOOR LIGHTS, LED DRIVERS, LED LIGHTS, LIGHTING, MODULAR FITTING
Luceco UK SQUARE LUXPANEL 600mm X 600mm 4800K Neutral White/2 years warranty
ELECTRICAL FITTINGS, Electro, INDOOR LIGHTS, LED DRIVERS, LED LIGHTS, LIGHTING, MODULAR FITTINGLuceco UK SQUARE LUXPANEL 600mm X 600mm 4800K Neutral White/2 years warranty
Slimline LED panel suitable for wide range of applications including offices, education and commercial spaces. Slimline design is ideal for low ceiling voids. Suitable for plasterboard or suspended ceiling systems. Plug and play driver and Luceco emergency pack compatible.
- 600 x 600 edgelit panel with white aluminum frame
- Precision aluminum frame with no visible corners
- Lumen outputs from 2800 Lumens with efficacy up to 110Llm/W
- Recessed to suit 15 or 24mm exposed T bar Ceiling
- IP20: For Indoor Use
- Cool White
- White Aluminium Frame
- Polycarbonate Diffuser
- Up to 30,000 Hours Life
- Non-Dimmable
LUMINAIRE PERFORMANCE
Light Output Ratio 100% Luminaire Efficacy 109.35 lm/W Light Distribution A40 ↓ 100.0% ↑ 0.0% CIE Flux Codes 47 78 95 100 101 SKU: Luceco1-1 -
CHINT
CHINT NU6-Ⅱ Low-voltage Surge Arrester 25 – 60A
NU6-Ⅱ Low-voltage Surge Arrester
- Certificates: international certificates are under proceeding;
- Number of poles: 1, 2,3, 4;
- Electric ratings: 230/400V, AC50Hz;
- Application: Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage;
- Standard: IEC 61643-1, EN 61643-11
SKU: n/a -
CEILING LIGHTS, ELECTRICAL FITTINGS, Electro, HOME&OFFICE LIGHTING, INDOOR LIGHTS, LED LIGHTS, LIGHTING
PHILIPS SPOTLIGHT RS100B LED2 830 3W WB 220-240V D55 (Warm White)
CEILING LIGHTS, ELECTRICAL FITTINGS, Electro, HOME&OFFICE LIGHTING, INDOOR LIGHTS, LED LIGHTS, LIGHTINGPHILIPS SPOTLIGHT RS100B LED2 830 3W WB 220-240V D55 (Warm White)
PHILIPS SPOTLIGHT RS100B LED2 830 3W WB 220-240V D55 (Warm White)
Driver included Color Temperature PF Luminous Flux
(LUMEN)Luminous
efficacyYes 3000K 0.5 280 80LM/W SKU: n/a -
CIRCUIT BREAKERS
IC60N – miniature circuit breaker – 3P – 63A – C curve
Main device application Distributionrange Acti 9product name Acti 9 iC60product or component type Miniature circuit-breakerdevice short name IC60Npoles description 3Pnumber of protected poles 3[In] rated current 63 Anetwork type DC
ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
36 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2standards EN 60898-1
EN 60947-2
IEC 60898-1
IEC 60947-2Complementary network frequency 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 15 kA 75 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
7.5 kA 75 % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz
4.5 kA 75 % conforming to EN 60947-2 – 440 V AC 50/60 Hz
15 kA 75 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7.5 kA 75 % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz
4.5 kA 75 % conforming to IEC 60947-2 – 440 V AC 50/60 Hz
27 kA 75 % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz
27 kA 75 % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 – 400 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 – 400 V AC 50/60 Hz
10 kA 100 % conforming to IEC 60947-2 – 125…180 V DC
10 kA 100 % conforming to EN 60947-2 – 125…180 V DC[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Fixedmounting support DIN railcomb busbar and distribution block compatibility Top or bottom: YES9 mm pitches 6height 85 mmwidth 54 mmdepth 78.5 mmnet weight 0.375 kgcolour Whitemechanical durability 20000 cycleselectrical durability 10000 cyclesconnections – terminals Single terminal (top or bottom) 1…35 mm² rigid
Single terminal (top or bottom) 1…25 mm² flexiblewire stripping length 14 mm for top or bottom connectiontightening torque 3.5 N.m top or bottomearth-leakage protection Separate blockSKU: n/a -
There are no reviews yet.