Cooker Unit Socket 6 x 6 MK Malaysia Brand
MK 6 x 6 COOKER UNIT
WHITE METAL SURFACE MOUNTED
COOKER UNIT WITH SOCKET AND NEON. 45 AMP DOUBLE POLE.
Condition:Ā New,Ā Type:Ā Cookers Switches,Ā Unit Type:Ā Unit
₦48,500.00
Compare-
Electro, Low Voltage Products and Systems, SCHNEIDER SECTIONS
EZC250N4250 circuit breaker, EasyPact EZC250N, TMD, 250A, 4 poles 3d
Electro, Low Voltage Products and Systems, SCHNEIDER SECTIONSEZC250N4250 circuit breaker, EasyPact EZC250N, TMD, 250A, 4 poles 3d
Main
Range of product EasyPact
Product or component type Circuit breaker
Device short name Easypact EZC250N
Circuit breaker name Easypact EZC250N
Device application Distribution
Poles description 4P
Protected poles description 3t
Network type AC
DC
Network frequency 50/60 Hz
[In] rated current 250 A at 40 Ā°C
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2
Breaking capacity code N
Breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 125 V DC 1P conforming to IEC 60947-2
20 kA Icu at 250 V DC 2P conforming to IEC 60947-2
8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
10 kA at 125 V DC conforming to IEC 60947-2
10 kA at 250 V DC conforming to IEC 60947-2
4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category ASKU: n/a -
SOLAR POWERED
Solar Panel Poly – PS15W
Poly solar panelPolycrystalline solar panelsĀ are also referred to as āmulti-crystalline,ā or many-crystal silicon. Because there are many crystals in each cell, there is to less freedom for the electrons to move. As a result,Ā polycrystalline solar panelsĀ have lower efficiency ratings thanĀ monocrystalline panels.We are a world-wide famous manufacturer in solar panel.We are aiming at providing affordable green energy for all.Try and change your lifestyle,you deserve it.15 years warrantySKU: n/a -
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONS
Acti9 iC60N 4P 40A C Miniature Circuit breaker A9F44440
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONSActi9 iC60N 4P 40A C Miniature Circuit breaker A9F44440
Main range Acti 9product name Disbo iC60product or component type Miniature circuit-breakerdevice short name IC60Npoles description 4Pnumber of protected poles 4[In] rated current 40Ā Anetwork type AC/DCtrip unit technology Thermal-magneticcurve code Cbreaking capacity 6Ā kA Icu at 100…133 V DC conforming to EN/IEC 60947-2
6000Ā A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
36Ā kA Icu at 12…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
20Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
10Ā kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
6Ā kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2utilisation category Category A conforming to EN/IEC 60947-2Complementary network frequency 50/60 Hz[Ue] rated operational voltage 440 V AC 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 27Ā kA 75Ā % conforming to EN/IEC 60947-2 – 12…133 V AC 50/60 Hz
15Ā kA 75Ā % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
7.5Ā kA 75Ā % conforming to EN/IEC 60947-2 – 380…415 V AC 50/60 Hz
4.5Ā kA 75Ā % conforming to EN/IEC 60947-2 – 440 V AC 50/60 Hz
6000Ā A 100Ā % conforming to EN/IEC 60898-1 – 415 V AC 50/60 Hz
6Ā kA 100Ā % conforming to EN/IEC 60947-2 – 100…133 V DClimitation class 3 conforming to EN/IEC 60947-2[Ui] rated insulation voltage 500Ā V AC 50/60 Hz[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN/IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Clip-onmounting support Rail9 mm pitches 8height 85Ā mmwidth 72Ā mmdepth 78.5Ā mmnet weight 0.5Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesprovision for padlocking Padlockableconnections – terminals Single terminal (top or bottom) 1ā¦35Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦25Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 3.5Ā N.m top or bottomearth-leakage protection Separate blockSKU: n/a -
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, Electro
Easy9 miniature circuit breaker- 2P – 25 A – C curve – 6000 A – 230 V
CIRCUIT BREAKERS, DISTRIBUTION BOARDS, ElectroEasy9 miniature circuit breaker- 2P – 25 A – C curve – 6000 A – 230 V
Schneider Electric Easy9 Miniature Circuit Breaker- 2P ā 6 A ā C Curve ā 6000 A ā 230 V
Main range Easy9device application Distributionproduct or component type Miniature circuit-breakerdevice short name Easy9 MCBPoles 2Pnumber of protected poles 2[In] rated current 25Ā Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000Ā A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1
6000Ā A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1suitability for isolation Yes conforming to IEC 60898-1Complementary network frequency 50/60 Hz[Ue] rated operational voltage 220 V AC 50/60 Hz
400 V AC 50/60 Hzmagnetic tripping limit 5…10 x In[Ics] rated service breaking capacity 6Ā kA 100Ā % x Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1[Ui] rated insulation voltage 500Ā V AC 50/60 Hz conforming to IEC 60898-1[Uimp] rated impulse withstand voltage 4Ā kV conforming to IEC 60898-1contact position indicator Yescontrol type Togglelocal signalling Withoutmounting mode Clip-onmounting support DIN rail9 mm pitches 4height 81Ā mmwidth 36Ā mmdepth 66.5Ā mmcolour Grey (RAL 7035)mechanical durability 10000Ā cycleselectrical durability 4000Ā cyclesconnections – terminals Tunnel type terminal (top or bottom) 1ā¦25Ā mmĀ² rigid
Tunnel type terminal (top or bottom) 1ā¦16Ā mmĀ² flexibletightening torque 2Ā N.m top or bottomearth-leakage protection WithoutEnvironment standards IEC 60898-1product certifications CEIP degree of protection IP20 conforming to IEC 60529pollution degree 2tropicalisation 2relative humidity 95Ā % at -5ā¦60Ā Ā°Cambient air temperature for operation -5ā¦60Ā Ā°Cambient air temperature for storage -40ā¦85Ā Ā°CSKU: n/a
There are no reviews yet.