Electro, LIGHT SWITCHES & ELECTRICAL SOCKETS
Schneider Hotel Key Card KB31EKT
device short name |
KB31
|
|
---|---|---|
product or component type |
Keycard switch
|
|
device presentation |
Complete mechanism
|
number of gangs |
1 gang
|
|
---|---|---|
Colour tint |
White
|
|
material |
Polycarbonate: grid plate
Polycarbonate: surround Polycarbonate: base |
|
projecting depth |
8Â mm
|
|
device mounting |
Flush
|
|
mounting support |
Wall mounted
|
|
fixing mode |
By screw M3.5
|
|
fixing center |
60.3 mm
|
|
embedding depth |
35Â mm
|
|
rated current |
16 A at 220…240 V AC, resistive load
|
|
network frequency |
50/60 Hz
|
|
connections – terminals |
Pillar terminal
|
|
terminal identifier |
L
N |
|
tightening torque |
0.4Â N.m
|
|
width |
86Â mm
|
|
height |
86Â mm
|
₦45,000.00
Compare-
Electro, SOCKETS & SWITCHES, SURGE PROTECTOR
Himel Single Phase Voltage Stabilizers 10kVA HTNDS10HB230 British type plug, 230 V output
Electro, SOCKETS & SWITCHES, SURGE PROTECTORHimel Single Phase Voltage Stabilizers 10kVA HTNDS10HB230 British type plug, 230 V output
Voltage stabilizer, HTND2, 10 kVA, British type plug, 230 V output
Main
Range of product                   -HTND2Product or component type          -Voltage stabilizerTechnology type                    -Servo motorRated power in VA                  -10 kVAOutlet standard                    -BritishProvided equipment                -User manualOutput voltage                      -230 VComplementary
Response time                        -1 sEfficiency                            -92 %Input voltage limits                   -140…250 VProtection type                       -Overvoltage
Short-circuit                          -UndervoltageNetwork frequency                    -50/60 HzMounting mode                       -Desktop installationEnvironment
Ambient air temperature for operation     -5…40 °CRelative humidity                        -0…90 %Humidity storage                        -0…90 %Operating altitude                        -0…2000 mStorage altitude                          -0…2000 mStandards                                -EN 61000-6-2
EN 61000-6-4                            -EN 61558-1Product certifications                      – CEPacking Units
Unit Type of Package 1Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â -PCENumber of Units in Package 1Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â -1SKU: n/a -
Electro, SCHNEIDER SECTIONS, Schneider Thorsman Testmeters
Thorsman BS Socket Tester IMT23103
Main product or component type Socket-outlet testeroutlet standard BritishComplementary local signalling Ground error by LCD displayfunction available RCD test functionrated voltage 220Â V 50…60 Hz +/- 10 %measurement category Category III 300Â Vresidual test current 30Â mA +/- 15 %RCD test time 60…300 mscontact voltage threshold < 35 V ACheight 77Â mmwidth 67Â mmdepth 66Â mmnet weight 70Â gSKU: n/a -
Electro, Low Voltage Products and Systems, SCHNEIDER SECTIONS
EZC100N4020 – Circuit breaker Easypact EZC100N – TMD – 20 A – 4 poles 3d
Electro, Low Voltage Products and Systems, SCHNEIDER SECTIONSEZC100N4020 – Circuit breaker Easypact EZC100N – TMD – 20 A – 4 poles 3d
Main range of product EasyPactproduct or component type Circuit breakerdevice short name Easypact EZC100Ncircuit breaker name Easypact EZC100Ndevice application Distributionpoles description 4Pprotected poles description 3tnetwork type DC
ACnetwork frequency 50/60 Hz[In] rated current 100 A at 40 °C[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2breaking capacity code Nbreaking capacity 10Â kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25Â kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
25Â kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
5Â kA Icu at 125 V DC 1P conforming to IEC 60947-2
5Â kA Icu at 250 V DC 2P conforming to IEC 60947-2
5Â kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
15Â kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
18Â kA Icu at 380…400 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service breaking capacity 5Â kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
2.5Â kA at 125 V DC conforming to IEC 60947-2
2.5Â kA at 250 V DC conforming to IEC 60947-2
2.5Â kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
12.5Â kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
12.5Â kA at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
9Â kA at 380…400 V AC 50/60 Hz conforming to IEC 60947-2
7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2suitability for isolation Yes conforming to IEC 60947-2utilisation category Category Atrip unit name TM-Dtrip unit technology Thermal-magnetictrip unit rating 20 A at 50 °Cprotection type Short-circuit protection
Overload protectionpollution degree 3 conforming to IEC 60947Complementary control type Togglemounting mode Fixedmounting support Backplateupside connection Frontdownside connection Frontmechanical durability 8500Â cycleselectrical durability Category A: 1500Â cycles 415 V AC 50/60 Hz conforming to IEC 60947-2connection pitch 25Â mmlocal signalling Positive contact indicationneutral protection setting Without protectionearth-leakage protection Withoutheight 130Â mmwidth 100Â mmdepth 60Â mmSKU: n/a -
Electro, SOCKETS & SWITCHES, SURGE PROTECTOR
Himel Single Phase Voltage Stabilizers 10kVA
Voltage stabilizer, HAVRL, relay type, 10 kVA, British type plug, 110/220 V output, 85..250 V input, with time delay
Main
Range of product                      – HAVRLProduct or component type             – Voltage stabilizerTechnology type                       – RelayOutlet standard                        – BritishProvided equipment                    – User manualComplementary
Rated power in VA                        – 10 kVAMinimum insulating resistance             – 5 MOhmMaximum [In] rated current                – 45 AEfficiency                                 – 90 %Input voltage limits                         – 85…250 VOptional feature                            – Bypass
Cooling fan
Input undervoltage protectionProtection type                            – Overvoltage
Overcurrent
Temperature rise protection
Time delayDisplay type                               –  LEDOutput voltage                             –  220 V AC +/- 8 %Network frequency                         –  50/60 HzEnvironment
Ambient air temperature for operation           -5…40 °CRelative humidity                              0…90 %Humidity storage                               0…90 %Operating altitude                              0…2000 mStorage altitude                                 0…2000 mStandards                                      EN 61000-6-2
EN 61000-6-4Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â EN 61558-1Packing Units
Unit Type of Package 1Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â PCENumber of Units in Package 1Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 1SKU: n/a
There are no reviews yet.