COMPUTING, PRINTERS
HP COLOUR LASERJET ENTERPRISE M652DN PRINTER
- Print only
- Print speed letter: Up to 50 ppm (black and color)
- Auto duplex printing; 2 paper trays (standard); Uses toner with JetIntelligence
- FCC Class A emissions – for use in commercial environments, not residential environments
₦498,000.00
Compare-
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONS
Easy9 switch disconnector – 2P – 63 A – 400 V EZ9S16263
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONSEasy9 switch disconnector – 2P – 63 A – 400 V EZ9S16263
Main range Easy9product or component type Switchdevice short name Easy9 switchswitch application DistributionPoles 2Putilisation category AC-22Asuitability for isolation YesComplementary [Ie] rated operational current 63Ā A at 400 V 50/60 Hz[Ue] rated operational voltage 400 V AC 50/60 Hz[Icm] rated short-circuit making capacity 0.945Ā kA[Icw] rated short-time withstand current 0.756Ā kA during 1 s[Ui] rated insulation voltage 500Ā V AC 50/60 Hz[Uimp] rated impulse withstand voltage 4Ā kVcontrol type Togglelocal signalling ON/OFF indicationcontact position indicator Yesmounting mode Clip-onmounting support DIN rail9 mm pitches 4height 81Ā mmwidth 36Ā mmdepth 66.5Ā mmcolour Greymechanical durability 8500Ā cycleselectrical durability 1500Ā cyclesconnections – terminals Tunnel type terminal (top or bottom) 1ā¦35Ā mmĀ² rigid
Tunnel type terminal (top or bottom) 1ā¦25Ā mmĀ² flexibletightening torque 3.5Ā N.mSKU: n/a -
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONS
Acti9 iC60N 2P 16A C Miniature Circuit breaker A9F44216
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONSActi9 iC60N 2P 16A C Miniature Circuit breaker A9F44216
Main range Acti 9product name Disbo iC60product or component type Miniature circuit-breakerdevice short name IC60Npoles description 2Pnumber of protected poles 2[In] rated current 16Ā Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 6Ā kA Icu at 100…133 V DC conforming to EN/IEC 60947-2
6000Ā A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
36Ā kA Icu at 12…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
20Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
10Ā kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
6Ā kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2utilisation category Category A conforming to EN/IEC 60947-2Complementary network frequency 50/60 Hz[Ue] rated operational voltage 440 V AC 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 27Ā kA 75Ā % conforming to EN/IEC 60947-2 – 12…133 V AC 50/60 Hz
15Ā kA 75Ā % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
7.5Ā kA 75Ā % conforming to EN/IEC 60947-2 – 380…415 V AC 50/60 Hz
4.5Ā kA 75Ā % conforming to EN/IEC 60947-2 – 440 V AC 50/60 Hz
6000Ā A 100Ā % conforming to EN/IEC 60898-1 – 415 V AC 50/60 Hz
6Ā kA 100Ā % conforming to EN/IEC 60947-2 – 100…133 V DClimitation class 3 conforming to EN/IEC 60947-2[Ui] rated insulation voltage 500Ā V AC 50/60 Hz[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN/IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Clip-onmounting support Rail9 mm pitches 4height 85Ā mmwidth 36Ā mmdepth 78.5Ā mmnet weight 0.25Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesprovision for padlocking Padlockableconnections – terminals Single terminal (top or bottom) 1ā¦25Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦16Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 2Ā N.m top or bottomearth-leakage protection Separate blockSKU: n/a -
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONS
IC60H – miniature circuit breaker – 1P – 50A – C curve A9F84150
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONSIC60H – miniature circuit breaker – 1P – 50A – C curve A9F84150
Main device application Distributionrange Acti 9product name Acti 9 iC60product or component type Miniature circuit-breakerdevice short name IC60Hpoles description 1Pnumber of protected poles 1[In] rated current 50Ā Anetwork type DC
ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000Ā A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
15Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
42Ā kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
30Ā kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Ā kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
20Ā kA Icu at 12…60 V DC conforming to EN/IEC 60947-2utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2standards IEC 60898-1
EN 60898-1
IEC 60947-2
EN 60947-2Complementary network frequency 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 21Ā kA 50Ā % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
21Ā kA 50Ā % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7500Ā A 75Ā % conforming to EN 60898-1 – 230 V AC 50/60 Hz
7500Ā A 75Ā % conforming to IEC 60898-1 – 230 V AC 50/60 Hz
15Ā kA 50Ā % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz
15Ā kA 50Ā % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz
15Ā kA 100Ā % conforming to EN 60947-2 – 72 V DC
15Ā kA 100Ā % conforming to IEC 60947-2 – 72 V DC
20Ā kA 100Ā % conforming to EN 60947-2 – 12…60 V DC
20Ā kA 100Ā % conforming to IEC 60947-2 – 12…60 V DC[Ui] rated insulation voltage 500Ā V AC 50/60 Hz conforming to EN 60947-2
500Ā V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN 60947-2
6Ā kV conforming to IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Fixedmounting support DIN railcomb busbar and distribution block compatibility Top or bottom: YES9 mm pitches 2height 85Ā mmwidth 18Ā mmdepth 78.5Ā mmnet weight 0.215Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesconnections – terminals Single terminal (top or bottom) 1ā¦35Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦25Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 3.5Ā N.m top or bottomearth-leakage protection WithoutSKU: n/a -
CEILING LIGHTS, ELECTRICAL FITTINGS, ELECTRICAL INDUSTRIAL, Electro, HIGH BAY LIGHTS, HOME&OFFICE LIGHTING, INTERIOR LIGHTING, LED LIGHTS, LIGHTING
Philip Highbay Light BY239P LED100/CW PSU 100watt Philips
CEILING LIGHTS, ELECTRICAL FITTINGS, ELECTRICAL INDUSTRIAL, Electro, HIGH BAY LIGHTS, HOME&OFFICE LIGHTING, INTERIOR LIGHTING, LED LIGHTS, LIGHTINGPhilip Highbay Light BY239P LED100/CW PSU 100watt Philips
General Information
Beam angle of light source – Ā°Light source color 865 cool daylightLight source replaceable NoNumber of gear units 1 unitDriver/power unit/transformer Power supply unitDriver included YesOptic type –Optical cover/lens type Polycarbonate bowl/cover foggyLuminaire light beam spread 100Ā°Control interface –Connection –Cable Cable 0.3 m without plugOperating and Electrical
Input Voltage 220 to 240 VInput Frequency 50 to 60 HzInitial CLO power consumption – WAverage CLO power consumption – WSKU: n/a
There are no reviews yet.