E12 2 x 40w max (excl.)
T5 HO 1 x 24w max (excl.)
T5 HO 1 x 39w max (excl.)
E12 2 x 40w max (excl.)
T5 HO 1 x 24w max (excl.)
T5 HO 1 x 39w max (excl.)
BRITISH STANDARD SOCKET OUTLET BELANKO –
2 GANG SP SWITCHED – 13 A – 250 V~
Colour: White T084
Material: Thermoplastic with glossy finish
86 x 146 x 9.5 mm (2 gang)
Supplied with 2 screws M3.5 for BS boxes
2.5mm 4 Core Armoured Cable is commonly found supplying mains voltage electricity to powered devices and networks. For example, it could be used to power outdoor buildings such as garden sheds or workshops as well as garden features such as jacuzzi/hot tubs.
The cable contains a steel wire armour, meaning it provides a mechanical protection for the insulating layers underneath. This also enables the cable to have higher pulling loads, making it perfectly suitable for dispensing from a cable drum on a building site, etc.
It’s construction is commonly identified by the plain annealed stranded copper for the cores, the PVC (Polyvinyl Chloride) for the bedding and sheathing, armour made from steel wire and XLPE (Cross-Linked Polyethylene) for the insulation.
The Steel Wire can also be used as a CPC (Circuit Protective Conductor), meaning the armour can be used an earth for the cable. This means that even though the cable has an earth core, it is still protected, meaning it abides by all health and safety regulations.
No. of cores / size of cable – 4
Approx overall diameter – 15.3mm
Approx weight (m) – 0.43Kg
Conductors – Plain Annealed Stranded Copper
Insulation – Cross-Linked Polyethylene (XLPE)
Bedding – PVC
Armour / Protection – Steel Wire
Sheath / Jacket – PVC
Colour – Black
Application – Primarily found within powered networks and providing mains electricity to powered devices.
Voltage Rating: – 600/1000Vt
APC Back-UPS 1400VA, 230V, AVR, IEC Sockets
Battery Backup & Surge Protector for Electronics and Computers
Includes : User Manual
1. Cold-start capable: Provides temporary battery power when the utility power is out.
2. Energy meter: Provides actual kilowatt hours of usage for energy conscious users.
3. Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
4. High online efficiency: Reduces utlility costs, generates less heat.
5. Intuitive LCD interface: Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
6. Predictive replace battery date: Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
7. Pure sine wave output on battery: Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
8. Single switched outlet group: Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
9. SmartSlot: Customize UPS capabilities with management cards.
10. Temperature-compensated battery charging: Prolongs battery life by regulating the charge voltage according to battery temperature.
Availability:
1. Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power.
2. Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
3. Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
4. Disconnected battery notification: Warns when a battery is not available to provide backup power.
5. Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
6. Temperature-compensated battery charging: Prolongs battery life by regulating the charge voltage according to battery temperature.
7. Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances.
Adaptability:
1. Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
2. Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Distribution transformers are typically oil-immersed and suitable for pole-, pad- or ground-mounting. They represent an economical option for certain networks, particularly those with low population densities.
Depending upon requirements, transformers may be connected between two phases of a three-phase system (two high voltage bushings) or from one phase to ground (single high voltage bushing).
The units are suitable for residential overhead distribution loads, as well as light commercial or industrial loads and diversified power applications.
Product scope
• Suitable for individual mounting, inner mounting holes and mounting brackets provided in enclosures.
• Sheet steel enclosure duly phosphatised and powder painted for longer life.
• Provision for door interlocking.
• Termination suitable for Aluminum cables, adequate knockouts provided in the enclosure for cable entry
630A, 63A, 400A, 200A,
There are no reviews yet.