In 1927, MEM embarked on a new field of manufacture – motor control gear, to meet the increasing use of electric motors in industry, and in 1965 announced its first miniature circuit breaker range. Delta Metal acquires MEM in 1971 to enter the electrical sector and Delta’s Electrical Division then consolidates several divisions of MEM (250V, 500V), as well as Bill Switchgear, under the “MEM” brand in 1998 The Electrical Division of Delta was acquired by Eaton Corporation in 2003, including the MEM, Bill and Holec brands, to spearhead the drive into global markets with products designed to meet international standards
MEM – Eaton 400A TPN Gear Switch
The top and bottom endplates are removable. Door can be removed for ease of installation. Incorporate knockouts and gasketed doors, IP41 rated protection. Handle: chromium-plated handles with ON (I) / OFF (O) indication. The switch can be locked ON or OFF by means of a padlock. Internal fixing: enables the unit to be mounted side by side with other units. Maximum current: 400A Number of Poles: 3 Poles. 3 Phase. Switches: quick make-and-break type, suitable for use on AC or DOC. Removable moving contact assemblies: to facilitate wiring. Interiors comprise porcelain bases fitted with non-ferrous conducting components.
₦855,000.00
CompareBased on 0 reviews
Be the first to review “MEM – Eaton 400A TPN Gear Switch”
-
WIRE CABLE TRAY & CABLE LADDER
Cable Tray Joiners
galvanised medium duty couplers
Couplers are required for joining together CTJ straight lengths or cut lengths of tray without the need for further drilling
CTJ standard couplers are supplied in pairs
CTJ standard coupler is supplied singlySKU: Joiner -
CIRCUIT BREAKERS
TeSys Schneider Electric Overload Relays 1.6 – 2.5amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.SKU: Overload3 -