Solar Panel YL270W Poly
Out of stock
The 60-cell polycrystalline module is currently one of the strongest in the market with 270 Wp output power. Compliant with advanced load tests – meets the load requirement of 5400 Pa. By optimizing the design of solar cells and selecting the right materials, the module achieves high efficiency even in a weaker light. Due to high corrosion resistance due to salt (fog) and ammonia, the modules are also suitable for agricultural and coastal surfaces.
Package includes:
Connection cable (L) with a width of 4.0 mm2 and a length of 900 mm; the toughened glass front has low iron content and is resistant to high temperatures; frame made of anodized aluminum alloy.
₦39,000.00
Out of stock
Compare-
COMPUTING, LAPTOPS
HP ProBook 450 G5 Notebook PC
Product details
SpecificationDescriptionWeightStarting at 2.10 kg (4.64 lb)NOTE:
Weight varies by configuration and components.Dimensions (W x D x H)Non-Touch37.60 x 26.40 x 2.10 cm (14.80 x 10.40 x 0.82 in) (front and rear)Touch37.60 x 26.40 x 2.30 cm (14.80 x 10.40 x 0.89 in) (front and rear)NOTE:
Height varies depending upon where on the notebook the measurement is made.Processors
SpecificationDescriptionIntel Core i7-8550UBasic frequency: 1.8 GHzUp to 3.7 GHz with Intel Turbo Boost Technology 2.08 MB cache4 coresIntel UHD Graphics 620Intel Core i5-8250UBasic frequency: 1.6 GHzUp to 3.4 GHz with Intel Turbo Boost Technology 2.06 MB cache4 coresIntel UHD Graphics 620Intel Core i3-7100U2.6 GHz3 MB cache2 coresIntel HD Graphics 620Intel Core i3-6006U2.0 GHz3 MB cache2 coresIntel HD Graphics 520Intel Celeron 3865U1.8 GHz2 MB cache2 coresIntel HD Graphics 610ChipsetIntegrated with processorGraphics
SpecificationDescriptionIntegratedIntel UHD graphics 620Intel HD graphics 620Intel HD graphics 610Intel HD graphics 520NOTE:
High-definition (HD) content is required to view high definition images.DiscreteNVIDIA GeForce 930MX (2 GB DDR3 dedicated memory, switchable)NOTE:
NVIDIA technology requires an Intel processor and NVIDIA GeForce discrete graphics configuration. This technology is available on Windows 10 Professional OS. With NVIDIA Optimus technology, full enablement of all discrete graphics video and display features might not be supported on all systems (for example, OpenGL applications that are run on the integrated GPU or the APU as applicable).SupportedHD decodeDirectX 12HDMI 1.4bDisplay
SpecificationDescriptionInternaleDP FHD Flat39.6 cm (15.6 in) diagonal FHD UWVA anti-glare flat LED backlit, 220 cd/m2, 45% sRGB (1920 x 1080)eDP HD Flat39.6 cm (15.6 in) diagonal HD SVA anti-glare LED-backlit, 220 cd/m2, 45% sRGB (1366 x 768)39.6 cm (15.6 in) diagonal HD SVA LED-backlit touch screen, 220 cd/m2, 45% sRGB (1366 x 768)NOTE:
High-definition (HD) content is required to view high definition images.Resolutions are dependent upon monitor capability, resolution and color depth settings.Storage/drives
SpecificationDescriptionSerial ATA drives500 GB 7200 rpm SATA Hard drive500 GB 5400 rpm, 8 GB cache, SATA SSHD Hard drive1 TB 5400 rpm SATA Hard driveM.2 2280 Solid State Drives (SSD)128 GB SATA TLC SSD256 GB PCIe NVMe Value SSD512 GB PCIe NVMe TLC SSDNOTE:
PCIe SSD not available for Celeron.SKU: n/a -
CABLE AND CABLE MANAGEMENT, Electro, SINGLE CORE WIRE
KABLEMETAL 10mm Single Core – Red
We offer other range of products across various categories and sub categories and our services are Procurement, installation and Management etc of electrical products, should you have any inquiry we are always here to do our best to promptly answer you.
SKU: n/a -
CABLE AND CABLE MANAGEMENT, Electro, SINGLE CORE WIRE
Doncaster Cables 6mm Single Core – Red
Product Description
Manufactured to BS 6004:2012 Table 3
Annealed Stranded Copper Conductor / PVC Insulated / PVC Sheathed. 300/500V
Designed for use in light industrial and domestic wiring. These cables are particularly suited for installation as meter tails and are intended for fixed installation in dry or damp premises.
These cables can be installed in conduit, in cable trunking and in cable ducting. Or where there is deemed little risk of mechanical damage these cables can be clipped direct, on cable tray, embedded or in free air. These cables are not intended to be laid underground.
Product Details
 Harmonisation Code Nominal Cross Sectional Area of Conductor (mm2) Nominal Stranding of Conductor (mm) Nominal Radial Thickness of insulation (mm) Nominal Radial Thickness of sheath (mm) Overall Diameter Lower Limit (mm) Overall Diameter Upper Limit (mm) Approximate Weight(kg/km) National Type 1.0 1 / 1.13 0.6 0.8 3.8 4.5 26 National Type 1.5 1 / 1.38 0.7 0.8 4.2 4.9 35 National Type 2.5 1 / 1.78 0.8 0.8 4.8 5.8 55 National Type 4.0 7 / 0.85 0.8 0.9 5.4 6.8 75 National Type 6.0 7 / 1.04 0.8 0.9 6.0 7.4 95 National Type 10.0 7 / 1.35 1.0 0.9 7.2 8.8 155 National Type 16.0 7 / 1.70 1.0 1.0 8.4 10.5 225 National Type 25.0 7 / 2.14 1.2 1.1 10.0 12.5 340 National Type 35.0 7 / 2.52 1.2 1.1 11.0 13.5 445 SKU: n/a -
Electro, Schneider "Consort Dado" Trunking, SCHNEIDER SECTIONS
Mita – Cableline 50 – end cap – 180W x 52 mm DPE3W
Electro, Schneider "Consort Dado" Trunking, SCHNEIDER SECTIONSMita – Cableline 50 – end cap – 180W x 52 mm DPE3W
Main product name Cableline 50product or component type End capcolour tint Whitequantity per set Set of 2Complementary trunking dimension 180W x 52 mmmaterial with surface finish UPVC (unplasticized polyvinyl chloride)Environment ambient air temperature for operation -5…60 °CPacking Units Unit Type of Package 1 PCENumber of Units in Package 1 1Package 1 Weight 60 gPackage 1 Height 2.5 cmPackage 1 width 5.5 cmPackage 1 Length 18.5 cmSKU: n/a -
Electro, Low Voltage Products and Systems, SCHNEIDER SECTIONS
EZC100F3020 – Circuit breaker Easypact EZC100F – TMD – 20 A – 3 poles 3d
Electro, Low Voltage Products and Systems, SCHNEIDER SECTIONSEZC100F3020 – Circuit breaker Easypact EZC100F – TMD – 20 A – 3 poles 3d
Main range of product EasyPactproduct or component type Circuit breakerdevice short name Easypact EZC100Fcircuit breaker name Easypact EZC100Fdevice application Distributionpoles description 3Pprotected poles description 3tnetwork type DC
ACnetwork frequency 50/60 Hz[In] rated current 100 A at 40 °C[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2breaking capacity code Fbreaking capacity 25Â kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
25Â kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
5Â kA Icu at 125 V DC 1P conforming to IEC 60947-2
5Â kA Icu at 250 V DC 2P conforming to IEC 60947-2
5Â kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
10Â kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
10Â kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2
7.5Â kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service breaking capacity 12.5Â kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
12.5Â kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
2.5Â kA at 125 V DC conforming to IEC 60947-2
2.5Â kA at 250 V DC conforming to IEC 60947-2
2.5Â kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
5Â kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
5Â kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2suitability for isolation Yes conforming to IEC 60947-2utilisation category Category Atrip unit name TM-Dtrip unit technology Thermal-magnetictrip unit rating 20 A at 50 °Cprotection type Short-circuit protection
Overload protectionpollution degree 3 conforming to IEC 60664-1
3 conforming to IEC 947-1SKU: n/a
There are no reviews yet.