TeSys LR9D and LR9F electronic overload relays provide simple, flexible and reliable motor protection.
TeSys Schneider Electric Overload Relays 2.3-4amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.
₦10,500.00
CompareBased on 0 reviews
Be the first to review “TeSys Schneider Electric Overload Relays 2.3-4amps”
-
DISTRIBUTION BOARDS, DISTRIBUTION BOARDS, Electro
Hager 6 Way 100A Single Phase Consumer Units DB C/W MCB
DISTRIBUTION BOARDS, DISTRIBUTION BOARDS, ElectroHager 6 Way 100A Single Phase Consumer Units DB C/W MCB
Features
These are most elegantly designed DBs, to suit the decor of homes
Raised neutral link for easy wiring
Spring loaded outer cover swings open by just pressing the lock as in case of Elegance series.
Supplied with masking sheet to protect components from cement during plastering
Supplied with neutral & earth link, top & bottom detachable platesSKU: 267 -
ELECTRICAL INDUSTRIAL, Electro, LADDERS
16 Feet Fiberglass Ladder
ladder comes in a vertical or inclined set of rungs or steps. There are two types: rigid ladders that can be leaned against a vertical surface such as a wall, and rope ladders that are hung from the top. The vertical members of a rigid ladder are called stringers or rails (US) or stiles (UK). Rigid ladders are usually portable, but some types are permanently fixed to buildings. They are commonly made of metal, wood, or Fiberglass, but they have been known to be made of tough plastic.
SKU: 302 -
CHANGEOVER SWITCHES, Electro, GEAR SWITCHES & CHANGEOVER
Standard 800Amps Changeover Switch
Features:
DMC terminal blocks are provided for cable termination having excellent mechanical, thermal and dielectric properties.
Side Handle Operation.
The enclosure is made of sheet steel suitable for individual mounting.
Terminals suitable for both Al. & Cu conductors.
Adequate knockouts provided for entry of cables.
Door interlocking facility provided.
mounting holes for switch ratings upto 320A and mounting brackets
for switch rating of 400A and above.SKU: Standard800 -
CIRCUIT BREAKERS
TeSys Schneider Electric Overload Relays 1.6 – 2.5amps
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.SKU: Overload3
There are no reviews yet.