Execution: Single pole, Double pole, Three pole, Four pole, SPN,TPN
Range: 10,15,20,30,40,63,80,100,125 etc Amp
Trip Free mechanism10KA short circuit breaking capacity for B and C Low power consumption,thus cost effective and energy savingFinger safe terminal IP20 degree of protectionDual Terminal Facility15 Plate Arc chute for effective arc quenchingsilver graphite contacts for enhance lifeAccessories switchPerformance and safetyPositive contact indicatorReliability and continuity of serviceSuitable for both DESB and switch boardShort Circuit breaking capacity 3KA MCBProtection against overload and short Circuit breaking capacity 3KA
₦20,000.00
CompareExecution: Single pole, Double pole, Three pole, Four pole, SPN,TPN
Range: 10,15,20,30,40,63,80,100,125 etc Amp
-For your safety, this product must be installed in accordance with local Building Regulations. If in any doubt, or where required by law, consult a competent person who is registered with an electrical self-certification scheme. Further information is available online or from your local authority-
Embedded perforations for :
– extra load capacity
– better aeration
– better stability
– better condensation drainage
Alternative perforations for :
– better fixation on the supports
– very useful for cable fixation
-Standard finish Galvanized
ladder comes in a vertical or inclined set of rungs or steps. There are two types: rigid ladders that can be leaned against a vertical surface such as a wall, and rope ladders that are hung from the top. The vertical members of a rigid ladder are called stringers or rails (US) or stiles (UK). Rigid ladders are usually portable, but some types are permanently fixed to buildings. They are commonly made of metal, wood, or Fiberglass, but they have been known to be made of tough plastic.
Widely used for the illumination of various marine platforms, chemical tankers, LNG ships and hazardous cargo wharf etc.
Can reliably work in severe environment exposed to moisture, vibration or corrosion;
Explosive hazardous atmosphere Zone 1, Zone 2, Zone 21 and Zone 22
Explosion -proof electronic ballast, wide voltage input
3-pole relays with screw clamp terminals
These overload relays are designed for the protection of motors. They are
compensated and phase failure sensitive. Resetting can either be manual or
automatic.
Direct mounting: under the contactor for versions with screw clamp terminals only;
pre-wired terminals, see pages B11/28 and B11/30.
Separate mounting: using terminal block LA7 K0064 (see below).
On the front face of the overload relay:
b selection of reset mode: Manual (marked H) or Automatic (marked A),
b red pushbutton: Trip Test function,
b blue pushbutton: Stop and manual Reset,
b yellow trip flag indicator: overload relay tripped.
Protection by magnetic circuit breaker GV2 LE, see pages A6/11 and A6/20.