Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONS
Easy9 miniature circuit breaker- 4P – 25 A – C curve – 6000 A – 400 V EZ9F56425
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONSEasy9 miniature circuit breaker- 4P – 25 A – C curve – 6000 A – 400 V EZ9F56425
Main range Easy9device application Distributionproduct or component type Miniature circuit-breakerdevice short name Easy9 MCBPoles 4Pnumber of protected poles 4[In] rated current 25Ā Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000Ā A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1
6000Ā A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1suitability for isolation Yes conforming to IEC 60898-1Complementary network frequency 50 Hz[Ue] rated operational voltage 220 V AC 50/60 Hz
400 V AC 50/60 Hzmagnetic tripping limit 5…10 x In[Ics] rated service breaking capacity 6Ā kA 100Ā % x Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1[Ui] rated insulation voltage 500Ā V AC 50/60 Hz conforming to IEC 60898-1[Uimp] rated impulse withstand voltage 4Ā kV conforming to IEC 60898-1contact position indicator Yescontrol type Togglelocal signalling Withoutmounting mode Clip-onmounting support DIN rail9 mm pitches 8height 81Ā mmwidth 72Ā mmdepth 66.5Ā mmcolour Grey (RAL 7035)mechanical durability 10000Ā cycleselectrical durability 4000Ā cyclesconnections – terminals Tunnel type terminal (top or bottom) 1ā¦25Ā mmĀ² rigid
Tunnel type terminal (top or bottom) 1ā¦16Ā mmĀ² flexibletightening torque 2Ā N.m top or bottomEnvironment standards IEC 60898-1product certifications VDE
CEIP degree of protection IP20 conforming to IEC 60529pollution degree 2tropicalisation 2relative humidity 95Ā % at -5ā¦60Ā Ā°Cambient air temperature for operation -5ā¦60Ā Ā°Cambient air temperature for storage -40ā¦85Ā Ā°CSKU: n/a -
Electro, Low Voltage Products and Systems, SCHNEIDER SECTIONS
EZC100F3025 – Circuit breaker Easypact EZC100F – TMD – 25 A – 3 poles 3d
Electro, Low Voltage Products and Systems, SCHNEIDER SECTIONSEZC100F3025 – Circuit breaker Easypact EZC100F – TMD – 25 A – 3 poles 3d
Main range of product EasyPactproduct or component type Circuit breakerdevice short name Easypact EZC100Fcircuit breaker name Easypact EZC100Fdevice application Distributionpoles description 3Pprotected poles description 3tnetwork type DC
ACnetwork frequency 50/60 Hz[In] rated current 100Ā A at 40Ā Ā°C[Ui] rated insulation voltage 690Ā V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6Ā kV conforming to IEC 60947-2[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2breaking capacity code Fbreaking capacity 25Ā kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
25Ā kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
5Ā kA Icu at 125 V DC 1P conforming to IEC 60947-2
5Ā kA Icu at 250 V DC 2P conforming to IEC 60947-2
5Ā kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
10Ā kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
10Ā kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2
7.5Ā kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service breaking capacity 12.5Ā kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
12.5Ā kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
2.5Ā kA at 125 V DC conforming to IEC 60947-2
2.5Ā kA at 250 V DC conforming to IEC 60947-2
2.5Ā kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
5Ā kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
5Ā kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
3.75Ā kA at 440 V AC 50/60 Hz conforming to IEC 60947-2suitability for isolation Yes conforming to IEC 60947-2utilisation category Category Atrip unit name TM-Dtrip unit technology Thermal-magnetictrip unit rating 25Ā A at 50Ā Ā°Cprotection type Short-circuit protection
Overload protectionpollution degree 3 conforming to IEC 60664-1
3 conforming to IEC 947-1Complementary control type Togglemounting mode Fixedmounting support Backplateupside connection Frontdownside connection Frontmechanical durability 8500Ā cycleselectrical durability Category A: 1500Ā cycles 415 V AC 50/60 Hz conforming to IEC 60947-2connection pitch 25Ā mmlocal signalling Positive contact indicationneutral protection setting Without protectionearth-leakage protection Withoutheight 130Ā mmwidth 75Ā mmdepth 60Ā mmSKU: n/a -
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONS
Switch disconnector iSW – 2P – 100 A – 415 V A9S65291 ISOLATOR SWITCH
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONSSwitch disconnector iSW – 2P – 100 A – 415 V A9S65291 ISOLATOR SWITCH
Main range Acti 9product name Acti 9 iSWproduct or component type Switch disconnectordevice short name ISWdevice application Isolation
Controlpoles description 2Putilisation category AC-22Asuitability for isolation YesComplementary [Ie] rated operational current 100Ā A at 415 V AC 50/60 Hz[Ue] rated operational voltage 415 V AC 50/60 Hz[Icm] rated short-circuit making capacity 5Ā kA switch-disconnector alone[Icw] rated short-time withstand current 1500Ā A[Ui] rated insulation voltage 500Ā V AC 50/60 Hz[Uimp] rated impulse withstand voltage 6Ā kVcontrol type Togglelocal signalling ON/OFF indicationcontact position indicator Yesmounting mode Fixedmounting support DIN railcomb busbar and distribution block compatibility Top or bottom: YES9 mm pitches 4height 85Ā mmwidth 36Ā mmdepth 73Ā mmcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesconnections – terminals Tunnel type terminals (top or bottom) – <= 1 x 50 mmĀ² – rigid
Tunnel type terminals (top or bottom) – <= 1 x 35 mmĀ² – flexible
Tunnel type terminals (top or bottom) – <= 1 x 35 mmĀ² – flexible with ferrulewire stripping length 9Ā mmtightening torque 3.5Ā N.mSKU: n/a -
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONS
Easy9 Residual Current Circuit Breaker – 4P – 63 A – 300 mA – AC type – 400 V EZ9R64463
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONSEasy9 Residual Current Circuit Breaker – 4P – 63 A – 300 mA – AC type – 400 V EZ9R64463
Main range of product Easy9product or component type Residual current circuit breaker (RCCB)device short name Easy9 RCCBPoles 4Pneutral position Left[In] rated current 63Ā Anetwork type ACearth-leakage sensitivity 300Ā mAearth-leakage protection time delay Instantaneousearth-leakage protection class Type ACrated breaking and making capacity 500Ā Arated conditional short-circuit current Easy9 MCB: 4500Ā A 63Ā AComplementary device location in system Outgoernetwork frequency 50 Hz[Ue] rated operational voltage 400 V AC 50 Hzresidual current tripping technology Voltage independent[Ui] rated insulation voltage 440Ā V AC[Uimp] rated impulse withstand voltage 4Ā kVsurge current 250Ā Acontact position indicator Yescontrol type Togglemounting mode Clip-onmounting support DIN railcomb busbar and distribution block compatibility Top: YES9 mm pitches 8height 82Ā mmwidth 72Ā mmdepth 72Ā mmcolour Grey (RAL 7035)mechanical durability 5000Ā cycleselectrical durability AC: 2000Ā cycles 400 V AC 50 Hzconnections – terminals Tunnel type terminal (top or bottom) 1ā¦35Ā mmĀ² rigid
Tunnel type terminal (top or bottom) 1ā¦25Ā mmĀ² flexibletightening torque 3.5Ā N.m top or bottommarket segment Residential
Small commercialSKU: n/a