MANUFACTURED FROM PURE ELECTROLYTIC COPPER.
COPPER LUGS & CABLE TERMINALS FROM 2.5 TO 1000 MM2 WITH DIFFERENT STUD HOLE SIZES AS REQUIRED .
LEAD FREE ELECTRO TIN PLATED TO PREVENT ATMOSPHERIC CORROSION.
CABLE LUGS ARE FULLY ANNEALED TO GUARANTEE OPTIMUM DUCTILITY.
UL, CUL CERTIFIED PRODUCT.
Copper Compression Cable Lugs Heavy Duty
Copper SC 16-10 – 10 Pcs
MANUFACTURED FROM PURE ELECTROLYTIC COPPER.
COPPER LUGS & CABLE TERMINALS FROM 2.5 TO 1000 MM2 WITH DIFFERENT STUD HOLE SIZES AS REQUIRED .
LEAD FREE ELECTRO TIN PLATED TO PREVENT ATMOSPHERIC CORROSION.
CABLE LUGS ARE FULLY ANNEALED TO GUARANTEE OPTIMUM DUCTILITY.
UL, CUL CERTIFIED PRODUCT.
₦3,000.00
CompareWeight | 0.6 kg |
---|
Based on 0 reviews
Be the first to review “Copper Compression Cable Lugs Heavy Duty”
-
ELECTRICAL FITTINGS, ELECTRICAL INDUSTRIAL, LED LIGHTS, OUTDOOR FITTINGS, OUTDOOR LIGHTS
Mureva lights, Floodlight 30W 4000K, IP44 IR Sensor 230V – Schneider Electric
ELECTRICAL FITTINGS, ELECTRICAL INDUSTRIAL, LED LIGHTS, OUTDOOR FITTINGS, OUTDOOR LIGHTSMureva lights, Floodlight 30W 4000K, IP44 IR Sensor 230V – Schneider Electric
Main range Murevarange of product Mureva lightsproduct name Floodlightproduct or component type Lampdevice application Ware-houses and parking garages
Residential
Media device support
Public areas
Secure lighting
Stadiums and arenasComplementary type of installation OutdoorTotal system power 30Ā Wlight source LED[Ue] rated operational voltage 230 V ACpower factor 0.9colour rendering index Ra=80luminous flux 3000Ā lmbulb lifespan 50000Ā hcolour temperature 4000Ā Kcolour Blackprovided equipment Sensorbeam angle 110Ā Ā°shape Rectangularheight 189.4Ā mmwidth 201.4Ā mmdepth 26.5Ā mmnet weight 820Ā gSKU: n/a -
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONS
Acti9 iC60N 2P 4A C Miniature Circuit breaker A9F44204
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONSActi9 iC60N 2P 4A C Miniature Circuit breaker A9F44204
Main range Acti 9product name Disbo iC60product or component type Miniature circuit-breakerdevice short name IC60Npoles description 2Pnumber of protected poles 2[In] rated current 4Ā Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 50Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
50Ā kA Icu at 12…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
50Ā kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
25Ā kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
6Ā kA Icu at 100…133 V DC conforming to EN/IEC 60947-2
6000Ā A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1utilisation category Category A conforming to EN/IEC 60947-2Complementary network frequency 50/60 Hz[Ue] rated operational voltage 440 V AC 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 50Ā kA 100Ā % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
50Ā kA 100Ā % conforming to EN/IEC 60947-2 – 12…133 V AC 50/60 Hz
50Ā kA 100Ā % conforming to EN/IEC 60947-2 – 380…415 V AC 50/60 Hz
25Ā kA 100Ā % conforming to EN/IEC 60947-2 – 440 V AC 50/60 Hz
6000Ā A 100Ā % conforming to EN/IEC 60898-1 – 415 V AC 50/60 Hz
6Ā kA 100Ā % conforming to EN/IEC 60947-2 – 100…133 V DClimitation class 3 conforming to EN/IEC 60947-2[Ui] rated insulation voltage 500Ā V AC 50/60 Hz[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN/IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Clip-onmounting support Rail9 mm pitches 4height 85Ā mmwidth 36Ā mmdepth 78.5Ā mmnet weight 0.25Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesprovision for padlocking Padlockableconnections – terminals Single terminal (top or bottom) 1ā¦25Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦16Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 2Ā N.m top or bottomearth-leakage protection Separate blockSKU: n/a -
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONS
Acti9 iC60N 1P 20A C Miniature Circuit breaker A9F44120
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONSActi9 iC60N 1P 20A C Miniature Circuit breaker A9F44120
Main range Acti 9product name Disbo iC60product or component type Miniature circuit-breakerdevice short name IC60Npoles description 1Pnumber of protected poles 1[In] rated current 20Ā Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 15Ā kA Icu at 12…48 V DC conforming to EN/IEC 60947-2
6Ā kA Icu at 72 V DC conforming to EN/IEC 60947-2
6000Ā A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1
36Ā kA Icu at 10…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
20Ā kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
10Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2utilisation category Category A conforming to EN/IEC 60947-2Complementary network frequency 50/60 Hz[Ue] rated operational voltage 240 V AC 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 27Ā kA 75Ā % conforming to EN/IEC 60947-2 – 10…60 V AC 50/60 Hz
15Ā kA 75Ā % conforming to EN/IEC 60947-2 – 100…133 V AC 50/60 Hz
7.5Ā kA 75Ā % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
6000Ā A 100Ā % conforming to EN/IEC 60898-1 – 240 V AC 50/60 Hz
15Ā kA 100Ā % conforming to EN/IEC 60947-2 – 12…48 V DC
6Ā kA 100Ā % conforming to EN/IEC 60947-2 – 72 V DClimitation class 3 conforming to EN/IEC 60947-2[Ui] rated insulation voltage 500Ā V AC 50/60 Hz[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN/IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Clip-onmounting support Rail9 mm pitches 2height 85Ā mmwidth 18Ā mmdepth 78.5Ā mmnet weight 0.125Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesprovision for padlocking Padlockableconnections – terminals Single terminal (top or bottom) 1ā¦25Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦16Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 2Ā N.m top or bottomearth-leakage protection Separate blockSKU: n/a -
SOLAR POWERED
Solar Panel YL275W Poly
The 60-cell polycrystalline module is currently one of the strongest in the market with 270 Wp output power. Compliant with advanced load tests – meets the load requirement of 5400 Pa. By optimizing the design of solar cells and selecting the right materials, the module achieves high efficiency even in a weaker light. Due to high corrosion resistance due to salt (fog) and ammonia, the modules are also suitable for agricultural and coastal surfaces.
Package includes:
Connection cable (L) with a width of 4.0 mm2 and a length of 900 mm; the toughened glass front has low iron content and is resistant to high temperatures; frame made of anodized aluminum alloy.
SKU: n/a -
SOLAR POWERED
Solar Panel Light PS80W Poly
Poly solar panel
Polycrystalline solar panelsĀ are also referred to as āmulti-crystalline,ā or many-crystal silicon. Because there are many crystals in each cell, there is to less freedom for the electrons to move. As a result,Ā polycrystalline solar panelsĀ have lower efficiency ratings thanĀ monocrystalline panels.
We are a world-wide famous manufacturer in solar panel.We are aiming at providing affordable green energy for all.Try and change your lifestyle,you deserve it.
10 years warranty
SKU: n/a
There are no reviews yet.