Schneider Circuit Breakers, SCHNEIDER SECTIONS
Acti9 iC60N 3P 32A C Miniature Circuit breaker A9F44332
Schneider Circuit Breakers, SCHNEIDER SECTIONSActi9 iC60N 3P 32A C Miniature Circuit breaker A9F44332
Main range Acti 9product name Disbo iC60product or component type Miniature circuit-breakerdevice short name IC60Npoles description 3Pnumber of protected poles 3[In] rated current 32Ā Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 6000Ā A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
36Ā kA Icu at 12…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
20Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
10Ā kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
6Ā kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Ā kA Icu at 100…133 V DC conforming to EN/IEC 60947-2utilisation category Category A conforming to EN/IEC 60947-2Complementary network frequency 50/60 Hz[Ue] rated operational voltage 440 V AC 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 27Ā kA 75Ā % conforming to EN/IEC 60947-2 – 12…133 V AC 50/60 Hz
15Ā kA 75Ā % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
7.5Ā kA 75Ā % conforming to EN/IEC 60947-2 – 380…415 V AC 50/60 Hz
4.5Ā kA 75Ā % conforming to EN/IEC 60947-2 – 440 V AC 50/60 Hz
6000Ā A 100Ā % conforming to EN/IEC 60898-1 – 415 V AC 50/60 Hz
15Ā kA 100Ā % conforming to EN/IEC 60947-2 – 100…133 V DClimitation class 3 conforming to EN/IEC 60947-2[Ui] rated insulation voltage 500Ā V AC 50/60 Hz[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN/IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Clip-onmounting support Rail9 mm pitches 6height 85Ā mmwidth 54Ā mmdepth 78.5Ā mmnet weight 0.375Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesprovision for padlocking Padlockableconnections – terminals Single terminal (top or bottom) 1ā¦35Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦25Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 3.5Ā N.m top or bottomearth-leakage protection Separate blockEnvironment standards EN/IEC 60947-2
EN/IEC 60898-1IP degree of protection IP20 conforming to IEC 60529pollution degree 3 conforming to EN/IEC 60947-2tropicalisation 2 conforming to IEC 60068-1relative humidity 95Ā % at 55Ā Ā°Cambient air temperature for operation -35ā¦70Ā Ā°Cambient air temperature for storage -40ā¦85Ā Ā°CSKU: n/a -
Low Voltage Products and Systems, SCHNEIDER SECTIONS
EZC250N3160 Circuit breaker Easypact EZC250N – TMD – 160 A – 3 poles 3d
Low Voltage Products and Systems, SCHNEIDER SECTIONSEZC250N3160 Circuit breaker Easypact EZC250N – TMD – 160 A – 3 poles 3d
Main range of product EasyPactproduct or component type Circuit breakerdevice short name Easypact EZC250Ncircuit breaker name Easypact EZC250Ndevice application Distributionpoles description 3Pprotected poles description 3tnetwork type DC
ACnetwork frequency 50/60 Hz[In] rated current 250Ā A at 40Ā Ā°C[Ui] rated insulation voltage 690Ā V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6Ā kV conforming to IEC 60947-2[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2breaking capacity code Nbreaking capacity 20Ā kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
50Ā kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
50Ā kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
20Ā kA Icu at 125 V DC 1P conforming to IEC 60947-2
20Ā kA Icu at 250 V DC 2P conforming to IEC 60947-2
25Ā kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
25Ā kA Icu at 400…415 V AC 50/60 Hz conforming to IEC 60947-2
8Ā kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service breaking capacity 10Ā kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
25Ā kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
10Ā kA at 125 V DC conforming to IEC 60947-2
10Ā kA at 250 V DC conforming to IEC 60947-2
25Ā kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
4Ā kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
12.5Ā kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
12.5Ā kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2suitability for isolation Yes conforming to IEC 60947-2utilisation category Category Atrip unit name TM-Dtrip unit technology Thermal-magnetictrip unit rating 160Ā A at 50Ā Ā°Cprotection type Overload protection
Short-circuit protectionpollution degree 3 conforming to IEC 60664-1
3 conforming to IEC 947-1Complementary control type Togglemounting mode Fixedmounting support Backplateupside connection Frontdownside connection Frontmechanical durability 10000Ā cycleselectrical durability Category A: 5000Ā cycles 415 V AC 50/60 Hz conforming to IEC 60947-2connection pitch 35Ā mmlocal signalling Positive contact indicationneutral protection setting Without protectionearth-leakage protection Withoutheight 165Ā mmwidth 105Ā mmdepth 60Ā mmSKU: n/a -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
Easy9 miniature circuit breaker- 3P – 20 A – C curve – 6000 A – 400 V EZ9F56320
Schneider Circuit Breakers, SCHNEIDER SECTIONSEasy9 miniature circuit breaker- 3P – 20 A – C curve – 6000 A – 400 V EZ9F56320
Main range Easy9device application Distributionproduct or component type Miniature circuit-breakerdevice short name Easy9 MCBPoles 3Pnumber of protected poles 3[In] rated current 20Ā Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000Ā A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1
6000Ā A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1suitability for isolation Yes conforming to IEC 60898-1Complementary network frequency 50 Hz[Ue] rated operational voltage 220 V AC 50/60 Hz
400 V AC 50/60 Hzmagnetic tripping limit 5…10 x In[Ics] rated service breaking capacity 6Ā kA 100Ā % x Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1[Ui] rated insulation voltage 500Ā V AC 50/60 Hz conforming to IEC 60898-1[Uimp] rated impulse withstand voltage 4Ā kV conforming to IEC 60898-1contact position indicator Yescontrol type Togglelocal signalling Withoutmounting mode Clip-onmounting support DIN rail9 mm pitches 6height 81Ā mmwidth 54Ā mmdepth 66.5Ā mmcolour Grey (RAL 7035)mechanical durability 10000Ā cycleselectrical durability 4000Ā cyclesconnections – terminals Tunnel type terminal (top or bottom) 1ā¦25Ā mmĀ² rigid
Tunnel type terminal (top or bottom) 1ā¦16Ā mmĀ² flexibletightening torque 2Ā N.m top or bottomSKU: n/a -
-
CEILING LIGHTS, ELECTRICAL FITTINGS, HOME&OFFICE LIGHTING
Philip LED Down Light Surface-mounted SmartBright 23watt Philips
CEILING LIGHTS, ELECTRICAL FITTINGS, HOME&OFFICE LIGHTINGPhilip LED Down Light Surface-mounted SmartBright 23watt Philips
Benefits
ā¢ Reliability and safety: meets national and international regulation
ā¢ Energy saving: High system efficacy with lower power consumption
ā¢ Diversity: One stop shopping with multiple choices of recess round, square as well
as surface-mount to fit your dedicated applications
ā¢ Easy to install with slim designFeatures
ā¢ Long life time: 20Khrs (L70B50@25Ā°C)
ā¢ System efficiency: up to 85lm/W
ā¢ One family offers recess round, square and surface mount options
ā¢ Slim design: 33mm housing body heightApplication
ā¢ Retail
ā¢ Office
ā¢ ResidentialSKU: n/a -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
Acti9 iC60N 4P 2A C Miniature Circuit breaker A9F44402
Schneider Circuit Breakers, SCHNEIDER SECTIONSActi9 iC60N 4P 2A C Miniature Circuit breaker A9F44402
Main range Acti 9product name Disbo iC60product or component type Miniature circuit-breakerdevice short name IC60Npoles description 4Pnumber of protected poles 4[In] rated current 2Ā Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 50Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
50Ā kA Icu at 12…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
50Ā kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
25Ā kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
6Ā kA Icu at 100…133 V DC conforming to EN/IEC 60947-2
6000Ā A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1utilisation category Category A conforming to EN/IEC 60947-2Complementary network frequency 50/60 Hz[Ue] rated operational voltage 440 V AC 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 50Ā kA 100Ā % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
50Ā kA 100Ā % conforming to EN/IEC 60947-2 – 12…133 V AC 50/60 Hz
50Ā kA 100Ā % conforming to EN/IEC 60947-2 – 380…415 V AC 50/60 Hz
25Ā kA 100Ā % conforming to EN/IEC 60947-2 – 440 V AC 50/60 Hz
6000Ā A 100Ā % conforming to EN/IEC 60898-1 – 415 V AC 50/60 Hz
6Ā kA 100Ā % conforming to EN/IEC 60947-2 – 100…133 V DClimitation class 3 conforming to EN/IEC 60947-2[Ui] rated insulation voltage 500Ā V AC 50/60 Hz[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN/IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Clip-onmounting support Rail9 mm pitches 8height 85Ā mmwidth 72Ā mmdepth 78.5Ā mmnet weight 0.5Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesprovision for padlocking Padlockableconnections – terminals Single terminal (top or bottom) 1ā¦25Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦16Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 2Ā N.m top or bottomearth-leakage protection Separate blockEnvironment standards EN/IEC 60898-1
EN/IEC 60947-2IP degree of protection IP20 conforming to IEC 60529pollution degree 3 conforming to EN/IEC 60947-2tropicalisation 2 conforming to IEC 60068-1relative humidity 95Ā % at 55Ā Ā°Cambient air temperature for operation -35ā¦70Ā Ā°Cambient air temperature for storage -40ā¦85Ā Ā°CSKU: n/a