COMPUTING, PRINTERS
HP LaserJet Enterprise M507dn (1PV87A) (Office Black and White Laser Printers)
- Print speed black:
- Normal: Up to 43 ppm (default) ; Up to 50 ppm (HP High Speed)Ā 1
- First page out (ready)
- Black: As fast as 5.9 secĀ 2
- Print quality black (best)
-
- Up to 1200 x 1200 dpi
- Print Resolution Technologies
- 300 dpi, 600 dpi, HP FastRes 1200, HP ProRes 1200
- Duty cycle (monthly, A4)
- Up to 150,000 pagesĀ 3
(Duty cycle is defined as the maximum number of pages per month of imaged output. This value provides a comparison of product robustness in relation to other HP LaserJet or HP Color LaserJet devices, and enables appropriate deployment of printers and MFPs to satisfy the demands of connected individuals or groups.)
- Recommended monthly page volume
- 2,000 to 7,500Ā 4
- Print technology
-
- Laser
- Processor speed
- 1.2 GHz
- Print languages
- HP PCL 6, HP postscript level 3 emulation, native PDF printing (v 1.7), Apple AirPrintā¢
- Display
-
- 6.86 cm (2.7 in) QVGA LCD (colour graphics)
₦240,000.00
Compare-
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONS
Miniature circuit-breaker, Acti9 iC60H, 2P, 50 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2) A9F84250
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONSMiniature circuit-breaker, Acti9 iC60H, 2P, 50 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2) A9F84250
Main device application Distributionrange Acti 9product name Acti 9 iC60product or component type Miniature circuit-breakerdevice short name IC60Hpoles description 2Pnumber of protected poles 2[In] rated current 50Ā Anetwork type AC
DCtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000Ā A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
42Ā kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
10Ā kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Ā kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
30Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Ā kA Icu at <= 125 V DC conforming to EN/IEC 60947-2
42Ā kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2standards IEC 60947-2
EN 60947-2
EN 60898-1
IEC 60898-1Complementary network frequency 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 15Ā kA 50Ā % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to EN 60947-2 – 380…415 V AC 50/60 Hz
5Ā kA 50Ā % conforming to EN 60947-2 – 440 V AC 50/60 Hz
15Ā kA 50Ā % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to IEC 60947-2 – 380…415 V AC 50/60 Hz
5Ā kA 50Ā % conforming to IEC 60947-2 – 440 V AC 50/60 Hz
7500Ā A 75Ā % conforming to EN 60898-1 – 400 V AC 50/60 Hz
7500Ā A 75Ā % conforming to IEC 60898-1 – 400 V AC 50/60 Hz
21Ā kA 50Ā % conforming to IEC 60947-2 – 12…133 V AC 50/60 Hz
21Ā kA 50Ā % conforming to EN 60947-2 – 12…133 V AC 50/60 Hz
15Ā kA 100Ā % conforming to IEC 60947-2 – 72…125 V DC
15Ā kA 100Ā % conforming to EN 60947-2 – 72…125 V DC[Ui] rated insulation voltage 500Ā V AC 50/60 Hz conforming to EN 60947-2
500Ā V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN 60947-2
6Ā kV conforming to IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Fixedmounting support DIN railcomb busbar and distribution block compatibility Top or bottom: YES9 mm pitches 4height 85Ā mmwidth 36Ā mmdepth 78.5Ā mmnet weight 0.25Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesconnections – terminals Single terminal (top or bottom) 1ā¦35Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦25Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 3.5Ā N.m top or bottomearth-leakage protection Separate blockSKU: n/a -
Electro, SOCKETS, SOCKETS & SWITCHES
WPB24 – BG 13A DOUBLE WEATHER PROOF SOCKET UNSWITCHED
13A Rated
Easy to install, supplied with fixing screws and installation instructions
IP55 rated with cover closed
20mm and 25mm knock-outs in the supplied mounting box
Adjustable horizontal and vertical fixing centres
Minimum mounting box depth: 25mm
Angled colour coded terminals with captive screws
Durable see through cover
Suitable for installation in outdoor locations, garages and sheds
Twin earth fitted as standard for high integrity circuits
SKU: n/a -
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONS
Easy9 switch disconnector – 2P – 63 A – 400 V EZ9S16263
Electro, Schneider Circuit Breakers, SCHNEIDER SECTIONSEasy9 switch disconnector – 2P – 63 A – 400 V EZ9S16263
Main range Easy9product or component type Switchdevice short name Easy9 switchswitch application DistributionPoles 2Putilisation category AC-22Asuitability for isolation YesComplementary [Ie] rated operational current 63Ā A at 400 V 50/60 Hz[Ue] rated operational voltage 400 V AC 50/60 Hz[Icm] rated short-circuit making capacity 0.945Ā kA[Icw] rated short-time withstand current 0.756Ā kA during 1 s[Ui] rated insulation voltage 500Ā V AC 50/60 Hz[Uimp] rated impulse withstand voltage 4Ā kVcontrol type Togglelocal signalling ON/OFF indicationcontact position indicator Yesmounting mode Clip-onmounting support DIN rail9 mm pitches 4height 81Ā mmwidth 36Ā mmdepth 66.5Ā mmcolour Greymechanical durability 8500Ā cycleselectrical durability 1500Ā cyclesconnections – terminals Tunnel type terminal (top or bottom) 1ā¦35Ā mmĀ² rigid
Tunnel type terminal (top or bottom) 1ā¦25Ā mmĀ² flexibletightening torque 3.5Ā N.mSKU: n/a -
Electro, SOCKETS & SWITCHES, SURGE PROTECTOR
Himel Single Phase Voltage Stabilizers 10kVA HTNDS10HB230 British type plug, 230 V output
Electro, SOCKETS & SWITCHES, SURGE PROTECTORHimel Single Phase Voltage Stabilizers 10kVA HTNDS10HB230 British type plug, 230 V output
Voltage stabilizer, HTND2, 10 kVA, British type plug, 230 V output
Main
Range of productĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -HTND2Product or component typeĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā -Voltage stabilizerTechnology typeĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -Servo motorRated power in VAĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -10Ā kVAOutlet standardĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -BritishProvided equipmentĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -User manualOutput voltageĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -230 VComplementary
Response timeĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -1 sEfficiencyĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -92Ā %Input voltage limitsĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -140…250 VProtection typeĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -Overvoltage
Short-circuitĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -UndervoltageNetwork frequencyĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -50/60 HzMounting modeĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -Desktop installationEnvironment
Ambient air temperature for operationĀ Ā Ā Ā Ā -5ā¦40Ā Ā°CRelative humidityĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -0ā¦90Ā %Humidity storageĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -0ā¦90Ā %Operating altitudeĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -0…2000 mStorage altitudeĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -0ā¦2000Ā mStandardsĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -EN 61000-6-2
EN 61000-6-4Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -EN 61558-1Product certificationsĀ Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā – CEPacking Units
Unit Type of Package 1Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -PCENumber of Units in Package 1Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā Ā -1SKU: n/a
There are no reviews yet.