CHINT
NX8 ā MCB CHINT . ELECTRIC BOX 8way
The MCB CHINT NX8 plastic electrical cabinet box is compact, sturdy, and has a high finish.
Can be used as a wall cabinet or used as a floating cabinet due to its versatile design.Ā There are error lights, power failure.
ABS plastic helps to withstand factors such as heat, sunlight, increasing the life of the cabinet.Ā The lid of the cabinet is made of transparent PC plastic, making it easy to see the equipment inside.Ā Available with 4-sided wiring hole.
Standard DIN Rail, convenient to connect and install equipment
Parameters of MCB CHINT NX8 . plastic electrical cabinet box
- Material: ABS/PC . plastic
- Type: Wall mounted plastic electrical cabinet
- Protection level: IP30
- Meets standards: IEC/EN 60439-3 (IEC/EN 60670-24)
- Application: in civil electricity, industrial electricity, solar power
SKU: n/a -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
Easy9 switch disconnector – 2P – 125 A – 400 V EZ9S16292
Schneider Circuit Breakers, SCHNEIDER SECTIONSEasy9 switch disconnector – 2P – 125 A – 400 V EZ9S16292
Main range Easy9product or component type Switchdevice short name Easy9 switchswitch application DistributionPoles 2Putilisation category AC-22Asuitability for isolation YesComplementary [Ie] rated operational current 125Ā A at 400 V 50/60 Hz[Ue] rated operational voltage 400 V AC 50/60 Hz[Icm] rated short-circuit making capacity 1.875Ā kA[Icw] rated short-time withstand current 1.5Ā kA during 1 s[Ui] rated insulation voltage 500Ā V AC 50/60 Hz[Uimp] rated impulse withstand voltage 4Ā kVcontrol type Togglelocal signalling ON/OFF indicationcontact position indicator Yesmounting mode Clip-onmounting support DIN rail9 mm pitches 4height 81Ā mmwidth 36Ā mmdepth 66.5Ā mmcolour Greymechanical durability 7000Ā cycleselectrical durability 1000Ā cyclesconnections – terminals Tunnel type terminal (top or bottom) 1ā¦50Ā mmĀ² rigid
Tunnel type terminal (top or bottom) 1ā¦35Ā mmĀ² flexibletightening torque 3.5Ā N.mSKU: n/a -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
IC60H – miniature circuit breaker – 1P – 63A – C curve A9F84163
Schneider Circuit Breakers, SCHNEIDER SECTIONSIC60H – miniature circuit breaker – 1P – 63A – C curve A9F84163
Main device application Distributionrange Acti 9product name Acti 9 iC60product or component type Miniature circuit-breakerdevice short name IC60Hpoles description 1Pnumber of protected poles 1[In] rated current 63Ā Anetwork type DC
ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 10000Ā A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
15Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
42Ā kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
30Ā kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
15Ā kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
20Ā kA Icu at 12…60 V DC conforming to EN/IEC 60947-2utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2standards EN 60947-2
EN 60898-1
IEC 60898-1
IEC 60947-2Complementary network frequency 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 21Ā kA 50Ā % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
21Ā kA 50Ā % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz
7.5Ā kA 50Ā % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
7500Ā A 75Ā % conforming to EN 60898-1 – 230 V AC 50/60 Hz
7500Ā A 75Ā % conforming to IEC 60898-1 – 230 V AC 50/60 Hz
15Ā kA 50Ā % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz
15Ā kA 50Ā % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz
15Ā kA 100Ā % conforming to EN 60947-2 – 72 V DC
15Ā kA 100Ā % conforming to IEC 60947-2 – 72 V DC
20Ā kA 100Ā % conforming to EN 60947-2 – 12…60 V DC
20Ā kA 100Ā % conforming to IEC 60947-2 – 12…60 V DC[Ui] rated insulation voltage 500Ā V AC 50/60 Hz conforming to EN 60947-2
500Ā V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN 60947-2
6Ā kV conforming to IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Fixedmounting support DIN railcomb busbar and distribution block compatibility Top or bottom: YES9 mm pitches 2height 85Ā mmwidth 18Ā mmdepth 78.5Ā mmnet weight 0.215Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesconnections – terminals Single terminal (top or bottom) 1ā¦35Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦25Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 3.5Ā N.m top or bottomearth-leakage protection WithoutSKU: n/a -
LIGHT SWITCHES & ELECTRICAL SOCKETS, SCHNEIDER SECTIONS
1 Gang TV Socket Master, Silver Bronze E8431TVS_SZ
LIGHT SWITCHES & ELECTRICAL SOCKETS, SCHNEIDER SECTIONS1 Gang TV Socket Master, Silver Bronze E8431TVS_SZ
Main range ZENceloproduct or component type TV/FM/SAT socketTV socket type TVadditional information Mastercolour tint Silver bronzeComplementary device mounting Flush
Surfacenumber of gangs 1 gangwidth 87Ā mmheight 87Ā mmdepth 33.4Ā mmSKU: n/a -
SOLAR POWERED
Solar Panel YL275W Poly
The 60-cell polycrystalline module is currently one of the strongest in the market with 270 Wp output power. Compliant with advanced load tests – meets the load requirement of 5400 Pa. By optimizing the design of solar cells and selecting the right materials, the module achieves high efficiency even in a weaker light. Due to high corrosion resistance due to salt (fog) and ammonia, the modules are also suitable for agricultural and coastal surfaces.
Package includes:
Connection cable (L) with a width of 4.0 mm2 and a length of 900 mm; the toughened glass front has low iron content and is resistant to high temperatures; frame made of anodized aluminum alloy.
SKU: n/a
There are no reviews yet.