COMPUTING, PRINTERS
HP LASERJET ENTERPRISE M608X PRINTER
- Print only
- Print speed letter: Up to 65 ppm (black)
- Auto duplex printing; 3 paper trays (standard); 1200 sheet input; Uses toner with JetIntelligence
- FCC Class A emissions – for use in commercial environments, not residential
₦470,500.00
Compare-
Low Voltage Products and Systems, SCHNEIDER SECTIONS
EZC100N4063 Circuit breaker Easypact EZC100N – TMD – 63 A – 4 poles 3d
Low Voltage Products and Systems, SCHNEIDER SECTIONSEZC100N4063 Circuit breaker Easypact EZC100N – TMD – 63 A – 4 poles 3d
Main range of product EasyPactproduct or component type Circuit breakerdevice short name Easypact EZC100Ncircuit breaker name Easypact EZC100Ndevice application Distributionpoles description 4Pprotected poles description 3tnetwork type AC
DCnetwork frequency 50/60 Hz[In] rated current 100Ā A at 40Ā Ā°C[Ui] rated insulation voltage 690Ā V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage 6Ā kV conforming to IEC 60947-2[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2breaking capacity code Nbreaking capacity 10Ā kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25Ā kA Icu at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
25Ā kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
5Ā kA Icu at 125 V DC 1P conforming to IEC 60947-2
5Ā kA Icu at 250 V DC 2P conforming to IEC 60947-2
5Ā kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
15Ā kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
18Ā kA Icu at 380…400 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service breaking capacity 5Ā kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
2.5Ā kA at 125 V DC conforming to IEC 60947-2
2.5Ā kA at 250 V DC conforming to IEC 60947-2
2.5Ā kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
12.5Ā kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
12.5Ā kA at 110…130 V AC 50/60 Hz conforming to IEC 60947-2
9Ā kA at 380…400 V AC 50/60 Hz conforming to IEC 60947-2
7.5Ā kA at 415 V AC 50/60 Hz conforming to IEC 60947-2suitability for isolation Yes conforming to IEC 60947-2utilisation category Category Atrip unit name TM-Dtrip unit technology Thermal-magnetictrip unit rating 63Ā A at 50Ā Ā°Cprotection type Short-circuit protection
Overload protectionpollution degree 3 conforming to IEC 60947Complementary control type Togglemounting mode Fixedmounting support Backplateupside connection Frontdownside connection Frontmechanical durability 8500Ā cycleselectrical durability Category A: 1500Ā cycles 415 V AC 50/60 Hz conforming to IEC 60947-2connection pitch 25Ā mmlocal signalling Positive contact indicationneutral protection setting Without protectionearth-leakage protection Withoutheight 130Ā mmwidth 100Ā mmdepth 60Ā mmSKU: n/a -
Electro, SOLAR POWERED
Solar Panel MR300W Mono
330W Monocrystalline solar panel has cells built in for efficiency and durability. It is waterproof and can withstand a wide range of environmental conditions.
Features
āĀ Bypass diode minimizes the power drop by shade.ā White tempered glass, EVA resin,weather proof film and anodized aluminum frame to provide efficient protection from the severest environmental conditions.ā WaterproofāĀ Perfect for grid applications.ā Product guarantee 10 years.SKU: n/a -
Electro, SOCKETS & SWITCHES, SURGE PROTECTOR
15 AMPS AVS Sollatek UK BRAND
AVS15
Over & Under Voltage Protection for Air Conditioners, Freezers, Fridges & CoolersProtect against
- High voltage
- Low Voltage
- Spikes/surges
- Powerback surges
Ideal for
- Air conditioners
- Large Fridge/freezers
Max Current: 15 amps
Wait time: User adjustable from 2 minutes to 5 minutes
SKU: AVS:180801 -
Schneider Circuit Breakers, SCHNEIDER SECTIONS
Acti9 iC60N 4P 6A C Miniature Circuit breaker
Main range Acti 9product name Disbo iC60product or component type Miniature circuit-breakerdevice short name IC60Npoles description 4Pnumber of protected poles 4[In] rated current 6Ā Anetwork type ACtrip unit technology Thermal-magneticcurve code Cbreaking capacity 6000Ā A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
36Ā kA Icu at 12…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
20Ā kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
10Ā kA Icu at 380…415 V AC 50/60 Hz conforming to EN/IEC 60947-2
6Ā kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
6Ā kA Icu at 220…250 V DC conforming to EN/IEC 60947-2utilisation category Category A conforming to EN/IEC 60947-2Complementary network frequency 50/60 Hz[Ue] rated operational voltage 440 V AC 50/60 Hzmagnetic tripping limit 8 x In +/- 20 %[Ics] rated service breaking capacity 27Ā kA 75Ā % conforming to EN/IEC 60947-2 – 12…133 V AC 50/60 Hz
15Ā kA 75Ā % conforming to EN/IEC 60947-2 – 220…240 V AC 50/60 Hz
7.5Ā kA 75Ā % conforming to EN/IEC 60947-2 – 380…415 V AC 50/60 Hz
4.5Ā kA 75Ā % conforming to EN/IEC 60947-2 – 440 V AC 50/60 Hz
6000Ā A 100Ā % conforming to EN/IEC 60898-1 – 415 V AC 50/60 Hz
6Ā kA 100Ā % conforming to EN/IEC 60947-2 – 100…133 V DClimitation class 3 conforming to EN/IEC 60947-2[Ui] rated insulation voltage 500Ā V AC 50/60 Hz[Uimp] rated impulse withstand voltage 6Ā kV conforming to EN/IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling Trip indicatormounting mode Clip-onmounting support Rail9 mm pitches 8height 85Ā mmwidth 72Ā mmdepth 78.5Ā mmnet weight 0.5Ā kgcolour Whitemechanical durability 20000Ā cycleselectrical durability 10000Ā cyclesprovision for padlocking Padlockableconnections – terminals Single terminal (top or bottom) 1ā¦25Ā mmĀ² rigid
Single terminal (top or bottom) 1ā¦16Ā mmĀ² flexiblewire stripping length 14Ā mm for top or bottom connectiontightening torque 2Ā N.m top or bottomearth-leakage protection Separate blockEnvironment standards EN/IEC 60947-2
EN/IEC 60898-1IP degree of protection IP20 conforming to IEC 60529pollution degree 3 conforming to EN/IEC 60947-2tropicalisation 2 conforming to IEC 60068-1relative humidity 95Ā % at 55Ā Ā°Cambient air temperature for operation -35ā¦70Ā Ā°Cambient air temperature for storage -40ā¦85Ā Ā°CSKU: n/a -
There are no reviews yet.